1.6MW 160-Slot Whatsminer 2U Hydro Cooling Container (20HQ)

SKU: AP-HC20-M160

This 20ft hydro mining container supports 160 Whatsminer or Avalon 2U hydro rigs, also compatible with 104 Antminer 3U rigs for efficient hydro cooling, delivering 1.6MW capacity.

$84,500.00 – $126,000.00

In stock

Specification:

Apexto is now offering U.S.-based inventory and DDP (Delivered Duty Paid) shipping for customers in the U.S. For more details, pls. contact our sales team.

Order 2 or more machines to save on shipping costs! Contact our sales team now to secure the best rates.

Trusted by

  • Apexto Mining reviews on Trustpilot
  • WhatToMine
  • Kryptex
  • NiceHash

Payment Method

  • USD
  • USDT(TRC 20)
  • KAS
  • BTC
  • ETH
  • LTC
  • DOGE
  • USDC(ERC20)

160-Slot High-Density Hydro Cooling Container for Whatsminer 2U Series

CONTAINER CAPACITY

ASIC MINERS

160 UNITS

Housed at full load

TOTAL POWER

1,600 KW

Continuous electrical load

FORM FACTOR

Custom

Standard

COOLING

Hydro

Thermal management

POWER INPUT

380V–415V AC 50/60Hz

AVAILABILITY

Typical lead time 45 days • DDP Sea Shipping Available

⚙ Compatible Models View More ›

Show 1 more models

Product Description

Optimized for high density configurations, the 1.6MW 160-Slot Whatsminer 2U Hydro Cooling Container 20FT HQ maximizes physical space utilization.

Built to pack 160 Whatsminer 2U hydro servers into the same compact 20 foot frame, this scalable infrastructure manages a heavy 1600kW thermal load. It utilizes engineered high flow stainless steel manifolds and robust CDU circulation to guarantee uniform water pressure across all highly compressed server rows under continuous full load operations.

Ideal for footprint constrained sites seeking maximum hashing output and capital return, this highly integrated, space saving water cooling container minimizes total onsite land overhead while securing highly consistent thermal cooling performance globally.

Core Advantages

Internal Structure of the 1.6MW 160-Slot Whatsminer 2U Hydro-Cooling Container

01. Integrated All-in-One System

Integrates the server racks, CDU, power cabinet, and control unit into a single 20FT container for rapid on-site setup, minimizing civil engineering costs and deployment time.

Liquid Cooling Rack Whatsminer mining

02. Advanced CDU System

The CDU system manages critical heat exchange between the internal and external water loops, continuously regulating coolant flow, stabilizing loop pressure, and optimizing overall thermal efficiency.

1.6MW 160-Slot Whatsminer 2U Hydro-Cooling Container Cooling Piping

03. Redundant Dual-Loop Cooling

Engineered with seamless, single-piece dual-loop piping to prevent leaks, utilizing red markers for hot water and blue for cold to ensure continuous operations during power limits.

1.6MW 160-Slot Whatsminer 2U Hydro Cooling Container Details

04. Individual Power Switches

Every miner slot is equipped with an independent breaker, enabling safe, hot swappable maintenance on single units without disrupting any other operational units.

water cooling mining Container Leak Detection

05. Instant Leak Detection

Uses high-sensitivity, floor-mounted moisture-sensing ropes to instantly detect any coolant leaks, triggering immediate remote alarms and automatic power cutoffs to protect your hardware.

Bitcoin Mining Hydro Cooling Container

06. Standard 2U Server Racking

Racks specifically designed for 2U miners are custom matched with Whatsminer's series, featuring smooth sliding rails and drawer style setups to ensure effortless manual maintenance.

Full Specifications

External dimensions

L:6058mm、W:2438mm、H:2896mm

Internal dimensions

L:5860mm、W:2348mm、H:2720mm

Weight

4500KG

ModelAP-HC20-M160Installed capacity160 Seat
Installed powerload1600 KWPower of the light-duty vertical multistage pump30 kW
Power of the fluid replenishing pump0.2 KWTotal power of the dry cooling tower fan41.5 KW
Total power of the closed cooling tower fan17.6 KWTotal power of the closed cooling tower spray pump4 KW
System pipeline pressure0.2-0.4 MPAOperating temperature range of the system0-50 ℃
Coolant circulation demand of a single machine≥0.6 m³/hTotal demand for circulating coolant within the system≥1.7 m³
Molded Case Circuit Breaker125 AResidual Current Circuit Breaker400 A
Contactor9 AIntermediate relay24 V
CUL certified frequency converter380 V

160-Slot Whatsminer Hydro Cooling Container Product Brochure

Complete product specifications, installation guide, and operational instructions.

Certification Standards

Our products meet leading international standards for safety, reliability, and performance.

China Classification Society

Marine & offshore compliance

UL Listed

Safety tested & certified

CSA Certified

North American compliance

CE Marking

European conformity

Recommended Power Setup

Match your container deployment with the appropriate transformer capacity.

Get Transformer Recommendation →
2750 kVA Three-Phase Pad-Mounted Transformer

For 1 x 1.6 MW Container

2000 kVA Three-Phase Pad-Mounted Transformer

View 2000 kVA Transformer →

Complete Cooling Solutions

We design and manufacture a complete range of hydro cooling solutions for every scale, from hydro cooling cabinets and containers to CDUs and dry coolers.

❄️ Cooling Capacity
⚙️ Miner Slots
📏 Dimensions (L × W × H)
🏢 Application

100-Slot Whatsminer Hydro Container

1 MW
100 Slots
6,058 × 2,438 × 2,896 mm
Entry-Level Mining Sites

120-Slot Whatsminer Hydro Container

1.2 MW
120 Slots
6,058 × 2,438 × 2,896 mm
Commercial-Scale Operations

Compare

160-Slot Whatsminer Hydro Container

1.6 MW
160 Slots
6,058 × 2,438 × 2,896 mm
Industrial-Scale Projects

240-Slot Whatsminer Hydro Container

2.4 MW
240 Slots
1,3716 × 2,438 × 2,896 mm
Mega-Scale Mining Facilities

Real Results from Real Miners

View All >>

1.6MW 160-Slot Whatsminer 2U Hydro-Cooling Mining Container Case Study
Ciudad del Este, Paraguay

7x 1.6MW Hydro Project

Sustaining highly stable, high-yield operations under humid tropical climates.

+32%

Space Optimization

-25%

Cooling Power Draw

$1.1M

Annual Savings

View All >>

1.6MW 160-Slot Whatsminer 2U Hydro-Cooling Mining Container Case Study
Irkutsk, Russia

8 x 1.6MW Hydro Project

Maintaining highly consistent thermal dissipation across freezing winter seasons.

+100%

Operational Uptime

99.9%

System Reliability

120W USD

Energy Cost

View All >>

“

"Squeezing 1.6MW into a 20FT container gave us substantial space savings. The pre-wired setup allowed our Siberian team to go online quickly, ensuring highly reliable, consistent winter hashing."

— O&M Director, Irkutsk Mining Facility, Russia

Operating 160 Whatsminer servers in Paraguay’s humid climate was our main concern. This container’s engineered manifolds maintain extremely balanced water pressure, keeping our chip temperatures completely stable."

— VP of Operations, Ciudad del Este Site, Paraguay

Global Deployment

1.2+ GW

Cumulative delivered cooling capacity

Serving Mining Sites

50+

Countries and regions covered

160-Slot Whatsminer Hydro Cooling Container FAQs

Which specific ASIC models are compatible with this 160-slot container?

This 1.62MW container is custom engineered for MicroBT standard 2U hydro servers, fully supporting the Whatsminer M53, M63, M73, M6d, and M7d series with exact matching internal cabinet rack dimensions.

How does the system prevent thermal hotspots under the high heat density of 160 packed miners?

To handle the intense 1600kW load in a 20FT container, we utilize customized large diameter water manifolds and robust CDUs, guaranteeing uniform water pressure and balanced coolant flow across all slots.

What are the concrete requirements for site level grid and transformer integration for this 1.6MW load?

Engineered for heavy duty industrial electricity grids, this container connects seamlessly to a standard 2000kVA transformer, simplifying site level power distribution and lowering your total onsite project CapEx.

What is the anti-corrosion coating process and the heat-insulating capability of the container shell?

The shell utilizes a three coat painting process to enhance overall corrosion resistance, while the internal structure is lined with foil faced fireproof insulation cotton, improving thermal stability under high temperatures.

Will pump failures, sensor malfunctions, or environmental anomalies instantly alarm and be located in the backend system?

Yes. The backend integrates smart warning systems, triggering instant alarms during any equipment anomalies. This covers water pumps, sensor arrays, and fans, helping onsite operators quickly locate exact fault positions.

160-Slot High-Density Hydro Cooling Container for Whatsminer 2U Series

CONTAINER CAPACITY

Housed at full load
160 UNITS
Continuous electrical load
1,600 KW

Custom

Standard

Hydro

Thermal management

POWER INPUT

380V–415V AC 50/60Hz

AVAILABILITY

Typical lead time 45 days • DDP Sea Shipping Available

⚙ Compatible Models View More ›

Show 1 more models

Product Description

Optimized for high density configurations, the 1.6MW 160-Slot Whatsminer 2U Hydro Cooling Container 20FT HQ maximizes physical space utilization.

Built to pack 160 Whatsminer 2U hydro servers into the same compact 20 foot frame, this scalable infrastructure manages a heavy 1600kW thermal load. It utilizes engineered high flow stainless steel manifolds and robust CDU circulation to guarantee uniform water pressure across all highly compressed server rows under continuous full load operations.

Ideal for footprint constrained sites seeking maximum hashing output and capital return, this highly integrated, space saving water cooling container minimizes total onsite land overhead while securing highly consistent thermal cooling performance globally.

Core Advantages

Internal Structure of the 1.6MW 160-Slot Whatsminer 2U Hydro-Cooling Container

01. Integrated All-in-One System

Integrates the server racks, CDU, power cabinet, and control unit into a single 20FT container for rapid on-site setup, minimizing civil engineering costs and deployment time.

Liquid Cooling Rack Whatsminer mining

02. Advanced CDU System

The CDU system manages critical heat exchange between the internal and external water loops, continuously regulating coolant flow, stabilizing loop pressure, and optimizing overall thermal efficiency.

1.6MW 160-Slot Whatsminer 2U Hydro-Cooling Container Cooling Piping

03. Redundant Dual-Loop Cooling

Engineered with seamless, single-piece dual-loop piping to prevent leaks, utilizing red markers for hot water and blue for cold to ensure continuous operations during power limits.

1.6MW 160-Slot Whatsminer 2U Hydro Cooling Container Details

04. Individual Power Switches

Every miner slot is equipped with an independent breaker, enabling safe, hot swappable maintenance on single units without disrupting any other operational units.

water cooling mining Container Leak Detection

05. Instant Leak Detection

Uses high-sensitivity, floor-mounted moisture-sensing ropes to instantly detect any coolant leaks, triggering immediate remote alarms and automatic power cutoffs to protect your hardware.

Bitcoin Mining Hydro Cooling Container

06. Standard 2U Server Racking

Racks specifically designed for 2U miners are custom matched with Whatsminer's series, featuring smooth sliding rails and drawer style setups to ensure effortless manual maintenance.

Full Specifications

External dimensions

L:6058mm、W:2438mm、H:2896mm

Internal dimensions

L:5860mm、W:2348mm、H:2720mm

Weight

4500KG

ModelAP-HC20-M160Installed capacity160 Seat
Installed powerload1600 KWPower of the light-duty vertical multistage pump30 kW
Power of the fluid replenishing pump0.2 KWTotal power of the dry cooling tower fan41.5 KW
Total power of the closed cooling tower fan17.6 KWTotal power of the closed cooling tower spray pump4 KW
System pipeline pressure0.2-0.4 MPAOperating temperature range of the system0-50 ℃
Coolant circulation demand of a single machine≥0.6 m³/hTotal demand for circulating coolant within the system≥1.7 m³
Molded Case Circuit Breaker125 AResidual Current Circuit Breaker400 A
Contactor9 AIntermediate relay24 V
CUL certified frequency converter380 V

160-Slot Whatsminer Hydro Cooling Container Product Brochure

Complete product specifications, installation guide, and operational instructions.

Certification Standards

Our products meet leading international standards for safety, reliability, and performance.

China Classification Society

Marine & offshore compliance

UL Listed

Safety tested & certified

CSA Certified

North American compliance

CE Marking

European conformity

Recommended Power Setup

Match your container deployment with the appropriate transformer capacity.

Get Transformer Recommendation →
2750 kVA Three-Phase Pad-Mounted Transformer

For 1 x 1.6 MW Container

2000 kVA Three-Phase Pad-Mounted Transformer

View 2000 kVA Transformer →

Complete Cooling Solutions

We design and manufacture a complete range of hydro cooling solutions for every scale, from hydro cooling cabinets and containers to CDUs and dry coolers.

❄️ Cooling Capacity
⚙️ Miner Slots
📏 Dimensions (L × W × H)
🏢 Application

100-Slot Whatsminer Hydro Container

1 MW
100 Slots
6,058 × 2,438 × 2,896 mm
Entry-Level Mining Sites

120-Slot Whatsminer Hydro Container

1.2 MW
120 Slots
6,058 × 2,438 × 2,896 mm
Commercial-Scale Operations

Compare

160-Slot Whatsminer Hydro Container

1.6 MW
160 Slots
6,058 × 2,438 × 2,896 mm
Industrial-Scale Projects

240-Slot Whatsminer Hydro Container

2.4 MW
240 Slots
1,3716 × 2,438 × 2,896 mm
Mega-Scale Mining Facilities

Real Results from Real Miners

View All >>

1.6MW 160-Slot Whatsminer 2U Hydro-Cooling Mining Container Case Study

7x 1.6MW Hydro Project

Sustaining highly stable, high-yield operations under humid tropical climates.

+32%

Space Optimization

-25%

Cooling Power Draw

$1.1M

Annual Savings

View All >>

1.6MW 160-Slot Whatsminer 2U Hydro-Cooling Mining Container Case Study

8 x 1.6MW Hydro Project

Maintaining highly consistent thermal dissipation across freezing winter seasons.

+100%

Operational Uptime

99.9%

System Reliability

120W USD

Energy Cost

View All >>

“

"Squeezing 1.6MW into a 20FT container gave us substantial space savings. The pre-wired setup allowed our Siberian team to go online quickly, ensuring highly reliable, consistent winter hashing."

— O&M Director, Irkutsk Mining Facility, Russia

Operating 160 Whatsminer servers in Paraguay’s humid climate was our main concern. This container’s engineered manifolds maintain extremely balanced water pressure, keeping our chip temperatures completely stable."

— VP of Operations, Ciudad del Este Site, Paraguay

1.2+ GW

Cumulative delivered cooling capacity

50+

Countries and regions covered

160-Slot Whatsminer Hydro Cooling Container FAQs

This 1.62MW container is custom engineered for MicroBT standard 2U hydro servers, fully supporting the Whatsminer M53, M63, M73, M6d, and M7d series with exact matching internal cabinet rack dimensions.

To handle the intense 1600kW load in a 20FT container, we utilize customized large diameter water manifolds and robust CDUs, guaranteeing uniform water pressure and balanced coolant flow across all slots.

Yes. The backend integrates smart warning systems, triggering instant alarms during any equipment anomalies. This covers water pumps, sensor arrays, and fans, helping onsite operators quickly locate exact fault positions.

Customize Your Hydro Cooling Solution

Share your requirements below. Our consultants will contact you via WhatsApp or email within 24 hours with a custom-matched proposal.

Project Timeline

In-stock miners will ship within 3 business days. For bulk orders, please allow an additional 1-2 days via DHL Express, UPS, FedEx, or TNT.

Pre-order miner delivery times depend on the factory schedule. Estimated delivery dates are provided on the order page, but delays may occur due to production issues.

Shipments are processed on a first-paid, first-shipped basis. Once full payment is received, we aim to ship as quickly as possible. Payments via wire transfer (T/T) may take 3-7 business days to verify, while cryptocurrency payments typically take a few hours to 1 business day.

International shipping usually takes 5-8 business days, with remote locations potentially requiring 8-10 days.

*All sales are final and non-refundable. Please understand, this is an industry standard.

Recommended Devices