2.4MW 240-Slot Whatsminer 2U Hydro Cooling Container (40HQ)

This 40ft hydro mining container supports up to 240 Whatsminer 2U units for efficient hydro cooling, delivering a high-performance Bitcoin mining solution with 2.4MW capacity.

$138,000.00

In stock

Apexto is now offering U.S.-based inventory and DDP (Delivered Duty Paid) shipping for customers in the U.S. For more details, pls. contact our sales team.

Order 2 or more machines to save on shipping costs! Contact our sales team now to secure the best rates.

Trusted by

  • Apexto Mining reviews on Trustpilot
  • WhatToMine
  • Kryptex
  • NiceHash

Payment Method

  • USD
  • USDT(TRC 20)
  • KAS
  • BTC
  • ETH
  • LTC
  • DOGE
  • USDC(ERC20)

2.4MW 240-Slot Whatsminer 2U Hydro Cooling Container for Enterprise Mining

CONTAINER CAPACITY

ASIC MINERS

240 UNITS

Housed at full load

TOTAL POWER

2,400 KW

Continuous electrical load

FORM FACTOR

Custom

Standard

COOLING

Hydro

Thermal management

POWER INPUT

380V–415V AC 50/60Hz

AVAILABILITY

Typical lead time 45 days • DDP Sea Shipping Available

⚙ Compatible Models View More ›

Show 1 more models

Product Description

Built strictly to C class datacenter standards, the 2.4MW 240-Slot Whatsminer 2U Hydro Cooling Container 40FT HQ is engineered for high density, utility scale deployments.

This robust 40 foot container accommodates up to 240 Whatsminer 2U hydro servers, utilizing metal isolation panels to create distinct hot and cold aisle containment. It prioritizes operational security by physically separating water pipelines from electrical cabling, while integrating an advanced gas fire suppression system at the cabin entrance.

Backed by automated reclosing breakers and full compliance with international electrical standards, this turnkey, plug and play solution ensures stable thermal management and reliable, long term uptime globally.

Core Advantages

liquid cooler Container AI Data Center AP-HC40-M240

01. Datacenter-Style Layout

Features a structured datacenter layout built with multiple rack cabinet groups, each equipped with individual doors that can be opened or closed based on operational needs.

2.4MW-240-Slot-Whatminer-hydro-cooling-container-CDU

02. Advanced CDU System

Features an advanced CDU with water pumps, integrating a bottom pressure tank and auto refill pipe to achieve automatic water replenishment and pressure release safely.

hydro Cooling Rack Modular crypto mining

03. Individual Control Switches

Equips every rack slot with an independent power switch and breaker with one to one labels, allowing technicians to perform safe maintenance without interrupting wider operations.

Customization Whatsminer liquid cooling Container AP-HC40-M240-4

04. Electric Leakage Protection

Integrates auto reclosing circuit breakers, residual current protection, and lightning arrestors, instantly cutting off power during any electrical anomalies to safeguard standard miner hardware safely.

2.4MW-240-Slot-Whatminer-hydro-cooling-container

05. Power Distribution Cabinet

Houses heavy duty power cabinets with automated reclosing breakers, featuring tool free side screws that can be easily opened by hand for fast routine maintenance operations.

liquid cooling Container for Whatsminer AP-HC40-M240-3

06. Water & Electricity Isolation

Designed with a clear physical separation of water and electricity, this layout places all power cabinets on one side of the aisle and liquid manifolds on the other, ensuring reliable safety.

Full Specifications

External dimensions

L:13716mm、W:2438mm、H:2896mm

Internal dimensions

L:13500mm、W:2230mm、H:2660mm

Weight

7800KG

ModelAP-HC40-M240Installed capacity240 seat
Installed powerload2400 KWPower of the light-duty vertical multistage pump30 kW
Power of the fluid replenishing pump0.2 KWTotal power of the dry cooling tower fan58.1 KW
Total power of the closed cooling tower fan22.5 KWTotal power of the closed cooling tower spray pump7.5 KW
System pipeline pressure0.2-0.4 MPAOperating temperature range of the system0-50 ℃
Coolant circulation demand of a single machine≥0.6 m³/hTotal demand for circulating coolant within the system≥2.5 m³
Molded Case Circuit Breaker125 AResidual Current Circuit Breaker400 A
Contactor9 AIntermediate relay24 V
CUL certified frequency converter380 V

240-Slot Whatsminer Hydro Cooling Container Product Brochure

Complete product specifications, installation guide, and operational instructions.

Certification Standards

Our products meet leading international standards for safety, reliability, and performance.

China Classification Society

Marine & offshore compliance

UL Listed

Safety tested & certified

CSA Certified

North American compliance

CE Marking

European conformity

Recommended Power Setup

Match your container deployment with the appropriate transformer capacity.

Get Transformer Recommendation →
3000 kVA Pad Mount Three-Phase Transformer

For 1 x 2.4 MW Container

3000 kVA Three-Phase Pad-Mounted Transformer

View 3000 kVA Transformer →

Complete Cooling Solutions

We design and manufacture a complete range of hydro cooling solutions for every scale, from hydro cooling cabinets and containers to CDUs and dry coolers.

❄️ Cooling Capacity
⚙️ Miner Slots
📏 Dimensions (L × W × H)
🏢 Application

100-Slot Whatsminer Hydro Cooling Container

1 MW
100 Slots
6058 × 2438 × 2896 mm
Compact Mining Sites

120-Slot Whatsminer Hydro Container

1.2 MW
120 Slots
6058 × 2438 × 2896 mm
Commercial-Scale Mining

160-Slot Whatsminer Hydro Container

1.6 MW
160 Slots
6058 × 2438 × 2896 mm
Industrial-Scale Operations

Compare

240-Slot Whatsminer Hydro Container

2.4 MW
240 Slots
13716 × 2438 × 2896 mm
Mega-Scale Mining Facilities

Real Results from Real Miners

View All >>

Apexto 2.4MW Hydro Project
Tashkent, Uzbekistan

10 x 2.4MW Hydro Project

Sustaining stable high-yield operations under industrial grids.

+32%

Hashrate Stability

-25%

Cooling Power Draw

$1.8M

Annual Savings

View All >>

2.4MW 240-Slot Whatsminer Hydro Mining Container Deployment Case Study
Austin, United States

6 x 2.4MW Hydro Project

Defeating extreme Texas summer heat with advanced liquid-cooling.

+100%

Operational Uptime

-30%

Setup Time

99.9%

System Reliability

View All >>

“

"Texas summers are brutal, but these 2.4MW containers handled our M63 units smoothly. The flow-optimized manifolds prevented any thermal hotspots, delivering rock-solid performance even on 45°C days."

— VP of Operations, Austin Mining Site, USA

"Managing 240 heavy-duty Whatsminer M53 servers was easy with these 2.4MW containers. The redundant pump CDU kept our loop completely balanced, ensuring exceptionally stable hashrates in our Tashkent facility."

— O&M Director, Tashkent Mining Site, Uzbekistan

Global Deployment

1.2+ GW

Cumulative delivered cooling capacity

Serving Mining Sites

50+

Countries and regions covered

240-Slot Whatsminer Hydro Cooling Container FAQs

Which specific Whatsminer models are compatible with this 240-slot container?

It is engineered exclusively for standard Whatsminer 2U hydro server form factors, supporting up to 240 units of the M53, M53S, M63, M63S, M6D, M7D and M73 series with exact matching rack specs.

How does the electrical system safely handle the massive 2.4MW power load?

The container integrates high-conductivity copper busbars and industrial-grade power cabinets. Each slot features independent circuit breakers, delivering highly stable, safe electricity and robust overcurrent protection for all 240 heavy-duty ASIC servers.The container integrates high-conductivity copper busbars and industrial-grade power cabinets. Each slot features independent circuit breakers, delivering highly stable, safe electricity and robust overcurrent protection for all 240 heavy-duty ASIC servers.

What backup mechanisms prevent operational downtime if a water circulation pump fails?

Our advanced CDU features a redundant dual-pump system with instant, automatic failover. If one pump experiences an issue, the backup pump takes over immediately to ensure continuous water flow and zero downtime.

How does the container ensure uniform water pressure and cooling to all 240 high-power servers?

It utilizes custom-balanced, large-diameter stainless steel manifolds and precise hydraulic balancing. This guarantees consistent water pressure and steady coolant flow to every server rack, preventing localized thermal hot spots under continuous loads.

s this 40FT HQ container compliant with standard international shipping and freight regulations?

The container is a fully CSC-certified standard 40FT HQ frame. This allows for seamless, cost-effective shipping across international sea, rail, and land freight networks without requiring special transport permits.

2.4MW 240-Slot Whatsminer 2U Hydro Cooling Container for Enterprise Mining

CONTAINER CAPACITY

Housed at full load
240 UNITS
Continuous electrical load
2,400 KW

Custom

Standard

Hydro

Thermal management

POWER INPUT

380V–415V AC 50/60Hz

AVAILABILITY

Typical lead time 45 days • DDP Sea Shipping Available

⚙ Compatible Models View More ›

Show 1 more models

Product Description

Built strictly to C class datacenter standards, the 2.4MW 240-Slot Whatsminer 2U Hydro Cooling Container 40FT HQ is engineered for high density, utility scale deployments.

This robust 40 foot container accommodates up to 240 Whatsminer 2U hydro servers, utilizing metal isolation panels to create distinct hot and cold aisle containment. It prioritizes operational security by physically separating water pipelines from electrical cabling, while integrating an advanced gas fire suppression system at the cabin entrance.

Backed by automated reclosing breakers and full compliance with international electrical standards, this turnkey, plug and play solution ensures stable thermal management and reliable, long term uptime globally.

Core Advantages

liquid cooler Container AI Data Center AP-HC40-M240

01. Datacenter-Style Layout

Features a structured datacenter layout built with multiple rack cabinet groups, each equipped with individual doors that can be opened or closed based on operational needs.

2.4MW-240-Slot-Whatminer-hydro-cooling-container-CDU

02. Advanced CDU System

Features an advanced CDU with water pumps, integrating a bottom pressure tank and auto refill pipe to achieve automatic water replenishment and pressure release safely.

hydro Cooling Rack Modular crypto mining

03. Individual Control Switches

Equips every rack slot with an independent power switch and breaker with one to one labels, allowing technicians to perform safe maintenance without interrupting wider operations.

Customization Whatsminer liquid cooling Container AP-HC40-M240-4

04. Electric Leakage Protection

Integrates auto reclosing circuit breakers, residual current protection, and lightning arrestors, instantly cutting off power during any electrical anomalies to safeguard standard miner hardware safely.

2.4MW-240-Slot-Whatminer-hydro-cooling-container

05. Power Distribution Cabinet

Houses heavy duty power cabinets with automated reclosing breakers, featuring tool free side screws that can be easily opened by hand for fast routine maintenance operations.

liquid cooling Container for Whatsminer AP-HC40-M240-3

06. Water & Electricity Isolation

Designed with a clear physical separation of water and electricity, this layout places all power cabinets on one side of the aisle and liquid manifolds on the other, ensuring reliable safety.

Full Specifications

External dimensions

L:13716mm、W:2438mm、H:2896mm

Internal dimensions

L:13500mm、W:2230mm、H:2660mm

Weight

7800KG

ModelAP-HC40-M240Installed capacity240 seat
Installed powerload2400 KWPower of the light-duty vertical multistage pump30 kW
Power of the fluid replenishing pump0.2 KWTotal power of the dry cooling tower fan58.1 KW
Total power of the closed cooling tower fan22.5 KWTotal power of the closed cooling tower spray pump7.5 KW
System pipeline pressure0.2-0.4 MPAOperating temperature range of the system0-50 ℃
Coolant circulation demand of a single machine≥0.6 m³/hTotal demand for circulating coolant within the system≥2.5 m³
Molded Case Circuit Breaker125 AResidual Current Circuit Breaker400 A
Contactor9 AIntermediate relay24 V
CUL certified frequency converter380 V

240-Slot Whatsminer Hydro Cooling Container Product Brochure

Complete product specifications, installation guide, and operational instructions.

Certification Standards

Our products meet leading international standards for safety, reliability, and performance.

China Classification Society

Marine & offshore compliance

UL Listed

Safety tested & certified

CSA Certified

North American compliance

CE Marking

European conformity

Recommended Power Setup

Match your container deployment with the appropriate transformer capacity.

Get Transformer Recommendation →
3000 kVA Pad Mount Three-Phase Transformer

For 1 x 2.4 MW Container

3000 kVA Three-Phase Pad-Mounted Transformer

View 3000 kVA Transformer →

Complete Cooling Solutions

We design and manufacture a complete range of hydro cooling solutions for every scale, from hydro cooling cabinets and containers to CDUs and dry coolers.

❄️ Cooling Capacity
⚙️ Miner Slots
📏 Dimensions (L × W × H)
🏢 Application

100-Slot Whatsminer Hydro Cooling Container

1 MW
100 Slots
6058 × 2438 × 2896 mm
Compact Mining Sites

120-Slot Whatsminer Hydro Container

1.2 MW
120 Slots
6058 × 2438 × 2896 mm
Commercial-Scale Mining

160-Slot Whatsminer Hydro Container

1.6 MW
160 Slots
6058 × 2438 × 2896 mm
Industrial-Scale Operations

Compare

240-Slot Whatsminer Hydro Container

2.4 MW
240 Slots
13716 × 2438 × 2896 mm
Mega-Scale Mining Facilities

Real Results from Real Miners

View All >>

Apexto 2.4MW Hydro Project

10 x 2.4MW Hydro Project

Sustaining stable high-yield operations under industrial grids.

+32%

Hashrate Stability

-25%

Cooling Power Draw

$1.8M

Annual Savings

View All >>

2.4MW 240-Slot Whatsminer Hydro Mining Container Deployment Case Study

6 x 2.4MW Hydro Project

Defeating extreme Texas summer heat with advanced liquid-cooling.

+100%

Operational Uptime

-30%

Setup Time

99.9%

System Reliability

View All >>

“

"Texas summers are brutal, but these 2.4MW containers handled our M63 units smoothly. The flow-optimized manifolds prevented any thermal hotspots, delivering rock-solid performance even on 45°C days."

— VP of Operations, Austin Mining Site, USA

"Managing 240 heavy-duty Whatsminer M53 servers was easy with these 2.4MW containers. The redundant pump CDU kept our loop completely balanced, ensuring exceptionally stable hashrates in our Tashkent facility."

— O&M Director, Tashkent Mining Site, Uzbekistan

1.2+ GW

Cumulative delivered cooling capacity

50+

Countries and regions covered

240-Slot Whatsminer Hydro Cooling Container FAQs

It is engineered exclusively for standard Whatsminer 2U hydro server form factors, supporting up to 240 units of the M53, M53S, M63, M63S, M6D, M7D and M73 series with exact matching rack specs.

The container integrates high-conductivity copper busbars and industrial-grade power cabinets. Each slot features independent circuit breakers, delivering highly stable, safe electricity and robust overcurrent protection for all 240 heavy-duty ASIC servers.The container integrates high-conductivity copper busbars and industrial-grade power cabinets. Each slot features independent circuit breakers, delivering highly stable, safe electricity and robust overcurrent protection for all 240 heavy-duty ASIC servers.

Our advanced CDU features a redundant dual-pump system with instant, automatic failover. If one pump experiences an issue, the backup pump takes over immediately to ensure continuous water flow and zero downtime.

It utilizes custom-balanced, large-diameter stainless steel manifolds and precise hydraulic balancing. This guarantees consistent water pressure and steady coolant flow to every server rack, preventing localized thermal hot spots under continuous loads.

Customize Your Hydro Cooling Solution

Share your requirements below. Our consultants will contact you via WhatsApp or email within 24 hours with a custom-matched proposal.

Project Timeline

In-stock miners will ship within 3 business days. For bulk orders, please allow an additional 1-2 days via DHL Express, UPS, FedEx, or TNT.

Pre-order miner delivery times depend on the factory schedule. Estimated delivery dates are provided on the order page, but delays may occur due to production issues.

Shipments are processed on a first-paid, first-shipped basis. Once full payment is received, we aim to ship as quickly as possible. Payments via wire transfer (T/T) may take 3-7 business days to verify, while cryptocurrency payments typically take a few hours to 1 business day.

International shipping usually takes 5-8 business days, with remote locations potentially requiring 8-10 days.

*All sales are final and non-refundable. Please understand, this is an industry standard.

Recommended Devices