20-Slot 200kW Avalon 2U Hydro Cooling Rack

This modular Avalon hydro cooling cabinet features 200kW cooling capacity and supports up to 20 Avalon A1566HA hydro miners. Designed for scalable Bitcoin mining deployments, it supports customized CDU integration, multi-cabinet expansion, and optional dry cooler or closed-loop cooling tower configurations.

$12,350.00

In stock

Apexto is now offering U.S.-based inventory and DDP (Delivered Duty Paid) shipping for customers in the U.S. For more details, pls. contact our sales team.

Order 2 or more machines to save on shipping costs! Contact our sales team now to secure the best rates.

Trusted by

  • Apexto Mining reviews on Trustpilot
  • WhatToMine
  • Kryptex
  • NiceHash

Payment Method

  • USD
  • USDT(TRC 20)
  • KAS
  • BTC
  • ETH
  • LTC
  • DOGE
  • USDC(ERC20)

Flexible 200kW hydro cooling hub for 20 WhatsMiner units

CONTAINER CAPACITY

ASIC MINERS

20 UNITS

Housed at full load

TOTAL POWER

200 KW

Continuous electrical load

FORM FACTOR

Custom

Standard

COOLING

Hydro

Thermal management

POWER INPUT

380V–415V AC 50/60Hz

AVAILABILITY

Typical lead time 15 days • DDP Sea Shipping Available

⚙ Compatible Models View More ›

Show 1 more models

Product Description

Designed for flexible Avalon 2U hydro mining deployments, this 20-slot 200kW split-type hydro cooling rack provides a scalable foundation for customized mining infrastructure.

The separated rack and heat dissipation configuration allows the cooling system to be arranged according to available space, site conditions, and project requirements. Its modular architecture supports customized CDU capacity, pump configuration, and heat rejection equipment, making it easier to match different cooling loads and deployment plans. The system can also be expanded with additional cooling or supporting equipment as mining capacity grows.

Suitable for warehouses, indoor facilities, and phased mining projects, it provides a flexible approach to building and upgrading hydro-cooled mining infrastructure.

Core Advantages

DCX HYDRO Crypto Mining Systems

01. Integrated All-in-One Design

The rack, CDU, power cabinet, and controller are all built into one single cabinet. Once delivered, simply connect the water pipes and power cables to start running—no complex assembly required.

liquid cooling for Blockchain

02. Leak-Proof Valve System

High-seal manifolds and reinforced pipes prevent coolant leaks at the source. Red and blue valves control hot and cold water; simply turn them off to isolate lines during maintenance with zero spills.

ASIC hydro cooling system

03. PDU Individual Breakers

The PDU power panel features a 1-to-1 breaker design, giving every single miner its own dedicated switch. If one unit needs servicing, just trip its specific breaker without affecting the rest of the rack.

cryptocurrency mining cabinet

04. Bottom Water Leak Detection

A water-sensing rope is installed along the bottom edge of the cabinet. If coolant leaks to the floor, it triggers an instant alarm so onsite staff can fix it before any miners get damaged.

Whatsminer miner Hydro Cooling System

05. Durable Fittings & Solid Build

Features 304 stainless steel manifolds, industry-standard aviation plugs, and reinforced high-pressure tubing with manual ball valves. Solidly sealed and durable for long-term use.

28-Slot 154kW Antminer liquid cooling Cabinet CDU

06. Customizable & Expandable CDU

The CDU shown is fully customizable and expandable. We can adjust its cooling capacity, pump specs, and expansion ports based on your specific site conditions, miner count, and heat rejection equipment.

Modular 1-to-N Infrastructure Scalability

The 1-to-N modular design enables flexible power expansion from 200kW up to 1,000kW, allowing mining sites to scale based on evolving demand. Featuring a customized high-flow pump system and a dedicated power control cabinet, this solution ensures reliable management across multiple racks—eliminating the need for major infrastructure overhauls as your hashrate grows.

Hydro cooling system for Whatsminer
Full Specifications

External dimensions

L:850mm、W:1000mm、H:2130mm

Internal dimensions

L:800mm、W:950mm、H:2080mm

Weight

230KG

ModelAP-X20Installed capacity20 Seat
Installed powerload200 kWPower of the light-duty vertical multistage pump4 kW
Power of the fluid replenishing pump0.2 kWTotal power of the dry cooling tower fan8.3 kW
Total power of the closed cooling tower fan2.2 kWTotal power of the closed cooling tower spray pump0.75 kW
System pipeline pressure0.2-0.4 MPAOperating temperature range of the system0-50 ℃
Coolant circulation demand of a single machine≥0.5 m³/hTotal demand for circulating coolant within the system≥0.25 m³
Residual Current Circuit Breaker400 AContactor9 A
Intermediate relay24 VCUL certified frequency converter380 V
Plug & Play with cooling system

20-Slot Avalon Modular Hydro Cooling Rack Product Brochure

Complete product specifications, installation guide, and operational instructions.

Certification Standards

Our products meet leading international standards for safety, reliability, and performance.

China Classification Society

Marine & offshore compliance

UL Listed

Safety tested & certified

CSA Certified

North American compliance

CE Marking

European conformity

Complete Cooling Solutions

We design and manufacture a complete range of hydro cooling solutions for every scale, from hydro cooling cabinets and containers to CDUs and dry coolers.

❄️ Cooling Capacity
⚙️ Miner Slots
📏 Dimensions (L × W × H)
🏢 Application

12-Slot Avalon Integrated Hydro Cooling Rack

120 kW
12 Slots
8,50 × 1,000 × 2,130 mm
Professional Home Setups

Compare

20-Slot Avalon Modular Hydro Cooling Rack

200 kW
20 Slots
8,50 × 1,000 × 2,130 mm
Modular Facility Scaling

100-Slot Avalon Hydro Cooling Container

1 MW
100 Slots
6,058 × 2,438 × 2,896 mm
Compact Mining Sites

160-Slot Avalon Hydro Cooling Container

1.6 MW
160 Slots
6,058 × 2,438 × 2,896 mm
Industrial-Scale Projects

Real Results from Real Miners

View All >>

Hydro Cooling System for ASIC Bitcoin Mining
Muscat, Oman

2 x 1-to-1 Standalone Setups

Operating two independent 1-to-1 systems with dedicated dry coolers to ensure maximum redundancy for 2U hydro miners in a high-heat environment.

100%

System Redundancy

+28%

Thermal Stability

120W USD

Independent Cluster

View All >>

2MW 200-Slot Whatsminer Hydro Mining Rack Deployment Case Study
Southeast Asia

1-to-5 High-Density Expansion

Utilizing one centralized high-flow CDU and a standalone power cabinet to drive five 20-slot racks, supporting a 100-unit Whatsminer 2U cluster.

+30%

Space Efficiency

-28%

Setup TimeSetup Time

1.1MW

Total Capacity

View All >>

“

"Deploying two separate 1-to-1 systems was a practical choice for our site. Since each 20-slot rack has its own dedicated CDU and radiator, we have complete redundancy. If we need to perform maintenance on one loop, the other rack continues to hash without any interruption. It’s a very reliable way to manage our 2U hardware."

— Infrastructure Lead, Oman Mining Site

"The 1-to-5 configuration allowed us to scale our hashrate quickly while keeping the warehouse organized. The customized high-flow CDU maintains perfect water pressure across all 100 miners. Having a dedicated power cabinet for the whole cluster makes electrical monitoring much easier and safer for our technicians."

— Site Manager, SE Asia Facility

Global Deployment

1.2+ GW

Cumulative delivered cooling capacity

Serving Mining Sites

50+

Countries and regions covered

20-Slot Avalon 2U Modular Hydro Cooling Rack FAQs

Can this rack run 20 Avalon A1566HA Hydro miners at the same time?

Yes. The rack is designed for up to 20 Avalon A1566HA Hydro miners and provides up to 200kW of installed miner capacity.

For example, the A1566HA 500T is rated at approximately 8.064kW per miner, so 20 units require about 161kW at rated power. This keeps a fully populated rack comfortably within the 200kW system capacity.

Why is the rack rated at 200kW when 20 A1566HA miners use less than 200kW?

The additional capacity provides operating headroom rather than sizing the cooling infrastructure exactly to the miners' nominal power.

This gives the system more flexibility for different A1566HA versions, normal power variation, and continuous high-load operation while avoiding a design that operates permanently at its maximum capacity.

Can different A1566HA versions be installed in the same rack?

Yes. Compatible A1566HA Hydro versions can be installed together in the same 20-slot rack.

For example, the 500T and 460T versions use the same 2U-sized chassis dimensions, while their rated power differs slightly. This allows operators to replace or add miners without requiring every slot to use exactly the same hashrate version.

Is 11m³/h enough coolant circulation for all 20 miners?

Yes. The CDU provides a rated flow of 11m³/h, while the cooling system specifies a minimum circulation requirement of 0.5m³/h per miner.

Twenty miners therefore require a minimum combined branch flow of approximately 10m³/h, and the system is designed around this full-rack circulation requirement.

How does the system keep coolant flow stable across 20 parallel miner branches?

The CDU uses PLC-based constant-flow control together with centralized circulation and pressure management.

Rather than relying only on a fixed pump output, the control system monitors operating conditions such as coolant flow, temperature, and pressure to support stable circulation as the rack operates under changing load conditions.

Does every 20-miner rack need its own CDU?

No. The split-type architecture supports both standalone and multi-cabinet configurations.

For larger projects, CDU capacity can be customized so multiple Avalon cooling racks share centralized cooling infrastructure. This reduces duplicated equipment and makes it easier to expand from a single 200kW rack toward a larger mining system.

Can I start with one Avalon rack and expand the cooling system later?

Yes. The system is designed for modular expansion from approximately 200kW up to 1000kW.

If future growth is planned from the beginning, the CDU, main piping, heat-rejection equipment, and monitoring infrastructure can be sized for additional racks, allowing mining capacity to be added without redesigning the entire cooling architecture.

When is this rack a better choice than building a custom cooling loop for Avalon miners?

This rack is a strong choice when you want a standardized 20-miner deployment instead of separately designing the manifold, circulation system, controls, electrical cabinet, and external heat-rejection system.

The rack, intelligent CDU, PLC control, and optional dry cooler or closed-loop cooling tower are designed as one coordinated cooling architecture, reducing the amount of engineering that must be completed separately on site.

Flexible 200kW hydro cooling hub for 20 WhatsMiner units

CONTAINER CAPACITY

Housed at full load
20 UNITS
Continuous electrical load
200 KW

Custom

Standard

Hydro

Thermal management

POWER INPUT

380V–415V AC 50/60Hz

AVAILABILITY

Typical lead time 15 days • DDP Sea Shipping Available

⚙ Compatible Models View More ›

Show 1 more models

Product Description

Designed for flexible Avalon 2U hydro mining deployments, this 20-slot 200kW split-type hydro cooling rack provides a scalable foundation for customized mining infrastructure.

The separated rack and heat dissipation configuration allows the cooling system to be arranged according to available space, site conditions, and project requirements. Its modular architecture supports customized CDU capacity, pump configuration, and heat rejection equipment, making it easier to match different cooling loads and deployment plans. The system can also be expanded with additional cooling or supporting equipment as mining capacity grows.

Suitable for warehouses, indoor facilities, and phased mining projects, it provides a flexible approach to building and upgrading hydro-cooled mining infrastructure.

Core Advantages

DCX HYDRO Crypto Mining Systems

01. Integrated All-in-One Design

The rack, CDU, power cabinet, and controller are all built into one single cabinet. Once delivered, simply connect the water pipes and power cables to start running—no complex assembly required.

liquid cooling for Blockchain

02. Leak-Proof Valve System

High-seal manifolds and reinforced pipes prevent coolant leaks at the source. Red and blue valves control hot and cold water; simply turn them off to isolate lines during maintenance with zero spills.

ASIC hydro cooling system

03. PDU Individual Breakers

The PDU power panel features a 1-to-1 breaker design, giving every single miner its own dedicated switch. If one unit needs servicing, just trip its specific breaker without affecting the rest of the rack.

cryptocurrency mining cabinet

04. Bottom Water Leak Detection

A water-sensing rope is installed along the bottom edge of the cabinet. If coolant leaks to the floor, it triggers an instant alarm so onsite staff can fix it before any miners get damaged.

Whatsminer miner Hydro Cooling System

05. Durable Fittings & Solid Build

Features 304 stainless steel manifolds, industry-standard aviation plugs, and reinforced high-pressure tubing with manual ball valves. Solidly sealed and durable for long-term use.

28-Slot 154kW Antminer liquid cooling Cabinet CDU

06. Customizable & Expandable CDU

The CDU shown is fully customizable and expandable. We can adjust its cooling capacity, pump specs, and expansion ports based on your specific site conditions, miner count, and heat rejection equipment.

Modular 1-to-N Infrastructure Scalability

The 1-to-N modular design enables flexible power expansion from 200kW up to 1,000kW, allowing mining sites to scale based on evolving demand. Featuring a customized high-flow pump system and a dedicated power control cabinet, this solution ensures reliable management across multiple racks—eliminating the need for major infrastructure overhauls as your hashrate grows.

Full Specifications

External dimensions

L:850mm、W:1000mm、H:2130mm

Internal dimensions

L:800mm、W:950mm、H:2080mm

Weight

230KG

ModelAP-X20Installed capacity20 Seat
Installed powerload200 kWPower of the light-duty vertical multistage pump4 kW
Power of the fluid replenishing pump0.2 kWTotal power of the dry cooling tower fan8.3 kW
Total power of the closed cooling tower fan2.2 kWTotal power of the closed cooling tower spray pump0.75 kW
System pipeline pressure0.2-0.4 MPAOperating temperature range of the system0-50 ℃
Coolant circulation demand of a single machine≥0.5 m³/hTotal demand for circulating coolant within the system≥0.25 m³
Residual Current Circuit Breaker400 AContactor9 A
Intermediate relay24 VCUL certified frequency converter380 V

20-Slot Avalon Modular Hydro Cooling Rack Product Brochure

Complete product specifications, installation guide, and operational instructions.

Certification Standards

Our products meet leading international standards for safety, reliability, and performance.

China Classification Society

Marine & offshore compliance

UL Listed

Safety tested & certified

CSA Certified

North American compliance

CE Marking

European conformity

Complete Cooling Solutions

We design and manufacture a complete range of hydro cooling solutions for every scale, from hydro cooling cabinets and containers to CDUs and dry coolers.

❄️ Cooling Capacity
⚙️ Miner Slots
📏 Dimensions (L × W × H)
🏢 Application

12-Slot Avalon Integrated Hydro Cooling Rack

120 kW
12 Slots
8,50 × 1,000 × 2,130 mm
Professional Home Setups

Compare

20-Slot Avalon Modular Hydro Cooling Rack

200 kW
20 Slots
8,50 × 1,000 × 2,130 mm
Modular Facility Scaling

100-Slot Avalon Hydro Cooling Container

1 MW
100 Slots
6,058 × 2,438 × 2,896 mm
Compact Mining Sites

160-Slot Avalon Hydro Cooling Container

1.6 MW
160 Slots
6,058 × 2,438 × 2,896 mm
Industrial-Scale Projects

Real Results from Real Miners

View All >>

Hydro Cooling System for ASIC Bitcoin Mining

2 x 1-to-1 Standalone Setups

Operating two independent 1-to-1 systems with dedicated dry coolers to ensure maximum redundancy for 2U hydro miners in a high-heat environment.

100%

System Redundancy

+28%

Thermal Stability

120W USD

Independent Cluster

View All >>

2MW 200-Slot Whatsminer Hydro Mining Rack Deployment Case Study

1-to-5 High-Density Expansion

Utilizing one centralized high-flow CDU and a standalone power cabinet to drive five 20-slot racks, supporting a 100-unit Whatsminer 2U cluster.

+30%

Space Efficiency

-28%

Setup TimeSetup Time

1.1MW

Total Capacity

View All >>

“

"Deploying two separate 1-to-1 systems was a practical choice for our site. Since each 20-slot rack has its own dedicated CDU and radiator, we have complete redundancy. If we need to perform maintenance on one loop, the other rack continues to hash without any interruption. It’s a very reliable way to manage our 2U hardware."

— Infrastructure Lead, Oman Mining Site

"The 1-to-5 configuration allowed us to scale our hashrate quickly while keeping the warehouse organized. The customized high-flow CDU maintains perfect water pressure across all 100 miners. Having a dedicated power cabinet for the whole cluster makes electrical monitoring much easier and safer for our technicians."

— Site Manager, SE Asia Facility

1.2+ GW

Cumulative delivered cooling capacity

50+

Countries and regions covered

20-Slot Avalon 2U Modular Hydro Cooling Rack FAQs

Yes. The rack is designed for up to 20 Avalon A1566HA Hydro miners and provides up to 200kW of installed miner capacity.

For example, the A1566HA 500T is rated at approximately 8.064kW per miner, so 20 units require about 161kW at rated power. This keeps a fully populated rack comfortably within the 200kW system capacity.

The additional capacity provides operating headroom rather than sizing the cooling infrastructure exactly to the miners' nominal power.

This gives the system more flexibility for different A1566HA versions, normal power variation, and continuous high-load operation while avoiding a design that operates permanently at its maximum capacity.

Yes. Compatible A1566HA Hydro versions can be installed together in the same 20-slot rack.

For example, the 500T and 460T versions use the same 2U-sized chassis dimensions, while their rated power differs slightly. This allows operators to replace or add miners without requiring every slot to use exactly the same hashrate version.

Yes. The CDU provides a rated flow of 11m³/h, while the cooling system specifies a minimum circulation requirement of 0.5m³/h per miner.

Twenty miners therefore require a minimum combined branch flow of approximately 10m³/h, and the system is designed around this full-rack circulation requirement.

The CDU uses PLC-based constant-flow control together with centralized circulation and pressure management.

Rather than relying only on a fixed pump output, the control system monitors operating conditions such as coolant flow, temperature, and pressure to support stable circulation as the rack operates under changing load conditions.

No. The split-type architecture supports both standalone and multi-cabinet configurations.

For larger projects, CDU capacity can be customized so multiple Avalon cooling racks share centralized cooling infrastructure. This reduces duplicated equipment and makes it easier to expand from a single 200kW rack toward a larger mining system.

Yes. The system is designed for modular expansion from approximately 200kW up to 1000kW.

If future growth is planned from the beginning, the CDU, main piping, heat-rejection equipment, and monitoring infrastructure can be sized for additional racks, allowing mining capacity to be added without redesigning the entire cooling architecture.

This rack is a strong choice when you want a standardized 20-miner deployment instead of separately designing the manifold, circulation system, controls, electrical cabinet, and external heat-rejection system.

The rack, intelligent CDU, PLC control, and optional dry cooler or closed-loop cooling tower are designed as one coordinated cooling architecture, reducing the amount of engineering that must be completed separately on site.

Customize Your Hydro Cooling Solution

Share your requirements below. Our consultants will contact you via WhatsApp or email within 24 hours with a custom-matched proposal.

Project Timeline

In-stock miners will ship within 3 business days. For bulk orders, please allow an additional 1-2 days via DHL Express, UPS, FedEx, or TNT.

Pre-order miner delivery times depend on the factory schedule. Estimated delivery dates are provided on the order page, but delays may occur due to production issues.

Shipments are processed on a first-paid, first-shipped basis. Once full payment is received, we aim to ship as quickly as possible. Payments via wire transfer (T/T) may take 3-7 business days to verify, while cryptocurrency payments typically take a few hours to 1 business day.

International shipping usually takes 5-8 business days, with remote locations potentially requiring 8-10 days.

*All sales are final and non-refundable. Please understand, this is an industry standard.

Recommended Devices