2.4MW 420-Slot Antminer Hydro Cooling Container (40HQ)

SKU: AP-HC40-A420

This 40ft hydro mining container supports up to 420 Antminer hydro units for efficient hydro cooling, delivering a high-performance Bitcoin mining solution with 2.4MW capacity.

$103,500.00 – $147,800.00

In stock

Specification:

Apexto is now offering U.S.-based inventory and DDP (Delivered Duty Paid) shipping for customers in the U.S. For more details, pls. contact our sales team.

Order 2 or more machines to save on shipping costs! Contact our sales team now to secure the best rates.

Trusted by

  • Apexto Mining reviews on Trustpilot
  • WhatToMine
  • Kryptex
  • NiceHash

Payment Method

  • USD
  • USDT(TRC 20)
  • KAS
  • BTC
  • ETH
  • LTC
  • DOGE
  • USDC(ERC20)

2.4MW 420-Slot Enterprise Hydro Cooling Container for Large-Scale Mining

CONTAINER CAPACITY

ASIC MINERS

420 UNITS

Housed at full load

TOTAL POWER

2,400 KW

Continuous electrical load

FORM FACTOR

Custom

Standard

COOLING

Hydro

Thermal management

POWER INPUT

380V–415V AC 50/60Hz

AVAILABILITY

Typical lead time 45 days • DDP Sea Shipping Available

⚙ Compatible Models View More ›

Show 1 more models

Product Description

Custom-designed for large-scale enterprise deployments, the 2.4MW 420-Slot Antminer Hydro Cooling Container 40FT HQ represents a highly secure, heavy-duty mining infrastructure.

Built with a reinforced steel frame and fireproof insulation, this robust 40-foot container is engineered to handle up to 420 Antminer hydro series units under continuous 2400kW thermal load. It integrates pre-wired Bitmain original cabling, a dedicated Gigabit fiber switch, and auto-reclosing breakers to safeguard ASIC hardware from any electrical anomalies.

Featuring seamless stainless manifolds and redundant water loops, this fully integrated, CE-compliant solution maximizes hashing uptime, simplifies maintenance, and secures operational security for high-density, megawatt-scale BTC mining.

Core Advantages

Internal Structure of the 2.4MW Slot Antminer Hydro Container

01. re-Wired Cabling & Signals

Equips every slot with genuine Bitmain power and network cables utilizing aviation plugs, paired with a dedicated Gigabit fiber switch to ensure stable, highly organized connectivity.

2.4 MW Antminer Hydro Container CDU Circulation System

02. Redundant Dual-Loop Cooling

Built with seamless, one-piece pipes to prevent welding leaks, this dual-loop system uses red markers for hot water inlets and blue for cold outlets, running reliably if one side loses power.

Internal Racks for 2.4MW Antminer Hydro Container

03. Leak-Free Stainless Manifolds

Features space saving built-in seamless stainless steel manifolds and mini ball valves with double sealed quick connectors, ensuring zero coolant leakage during any connection and disconnection.

2.4MW Slot Antminer Hydro Container Fan

04. Reinforced & Fireproof Structure

Features motorized louvers with dust filters, a fireproof insulation lining, internal-locking fasteners, and a reinforced cross-beam base to ensure robust, secure, and stable container operations.

2.4 MW Slot Antminer Hydro Container Centralized Power Distribution Cabinet

05. Automated Reclosing Breakers

Integrates auto-reclosing circuit breakers, independent rack power controls with 1-to-1 labels, and lightning protection, enabling safe electrical operations and instant automatic shutdowns during any anomalies.

2.4MW Slot Antminer Hydro Container Leak Detection Strip

06. Leak Detection System

Equipped with a moisture-sensing immersion rope, this system detects coolant leaks and triggers instant alarms, enhancing safety and preventing potential damage in liquid-cooled mining setups.

Full Specifications

External dimensions

L:12192mm、W:2438mm、H:2896mm

Internal dimensions

L:12000mm、W:2230mm、H:2660mm

Weight

9200KG

ModelAP-HC40-A420Installed capacity420 seat
Installed powerload2310 KWPower of the light-duty vertical multistage pump30 kW
Power of the fluid replenishing pump0.2 KWTotal power of the dry cooling tower fan99.6 KW
Total power of the closed cooling tower fan33 KWTotal power of the closed cooling tower spray pump8 KW
System pipeline pressure0.2-0.4 MPAOperating temperature range of the system22-42 ℃
Coolant circulation demand of a single machine≥0.5 m³/hTotal demand for circulating coolant within the system≥2.2 m³
Molded Case Circuit Breaker250 AResidual Current Circuit Breaker630 A
Contactor9 AIntermediate relay24 V
CUL certified frequency converter380 V

Antminer 420-Slot Antminer Hydro Cooling Container Product Brochure

Complete product specifications, installation guide, and operational instructions.

Certification Standards

Our products meet leading international standards for safety, reliability, and performance.

China Classification Society

Marine & offshore compliance

UL Listed

Safety tested & certified

CSA Certified

North American compliance

CE Marking

European conformity

Recommended Power Setup

Match your container deployment with the appropriate transformer capacity.

Get Transformer Recommendation →
3000 kVA Pad Mount Three-Phase Transformer

For 1 x 2.4 MW Container

3000 kVA Three-Phase Pad-Mounted Transformer

View 3000 kVA Transformer →

Complete Cooling Solutions

We design and manufacture a complete range of hydro cooling solutions for every scale, from hydro cooling cabinets and containers to CDUs and dry coolers.

❄️ Cooling Capacity
⚙️ Miner Slots
📏 Dimensions (L × W × H)
🏢 Application

308-Slot Antminer Hydro Cooling Container

1.7 MW
308 Slots
1,2192 × 2,438 × 2,896 mm
Standard Industrial Operations

364-Slot Antminer Hydro Cooling Container

2.1 MW
364 Slots
1,2192 × 2,438 × 2,896 mm
High-Density Mining Farms

Compare

420-Slot Antminer Hydro Cooling Container

2.4 MW
420 Slots
1,2192 × 2,438 × 2,896 mm
Mega-Scale Utility Projects

480-Slot Antminer Hydro Cooling Container

2.6 MW
480 Slots
1,2192 × 2,438 × 2,896 mm
Enterprise-Class Global Facilities

Real Results from Real Miners

View All >>

2.4 MW Slot Antminer Hydro Container Deployment Case Study
Edmonton, Canada

12 x 2.4MW Hydro Project

Sustaining stable large-scale operations under heavy thermal loads.

+32%

Cooling Efficiency

-25%

Cooling Power Draw

$1.5M$1.5M

Annual Savings

View All >>

480-Slot Antminer Hydro Cooling Container Case Study
Reykjavik, Iceland

5 x 2.4MW Hydro Project

Achieving zero-emission hydro mining with clean geothermal energy.

+100%

Operational Uptime

-30%

Setup Time

99.9%

System Reliability

View All >>

“

"Operating 420 miners under heavy industrial voltage requires uncompromising safety. These fully UL-certified containers with automatic reclosing breakers gave our Canadian site reliable power delivery and complete operational peace of mind."

— VP of Operations, Edmonton Mining Site, Canada

"Deploying five 2.4MW containers in Iceland's rugged environment was incredibly smooth. The reinforced, fireproof structure and pre-wired cabling made on-site installation effortless, delivering immediate eco-friendly hashing."

— O&M Director, Reykjavik Mining Site, Iceland

Global Deployment

1.2+ GW

Cumulative delivered cooling capacity

Serving Mining Sites

50+

Countries and regions covered

420-Slot Antminer Hydro Cooling Container FAQs

What is the electrical voltage compatibility of this container, and how is the PDU infrastructure designed?

Engineered for standard 380V three phase input, the integrated PDU cabinet delivers a stable, reliable power supply. This heavy-duty system is custom configured to fully accommodate the massive 2310kW total installed load of all 420 hydro miners under continuous full-load operations safely.

Can this 2.31MW container ensure zero hashrate downclocking during extreme summer temperatures above 45°C?

Yes. For extreme climates exceeding 40°C, we recommend upgrading the integrated dry cooler with an optional wet curtain system. This restricts chip inlet water temperatures strictly below 35°C, ensuring consistent, stable full load hashrates without any thermal downclocking on extremely hot summer days.

How does this high-density 40FT container ensure the water temperature difference between the first and last rows stays below 2°C?

By utilizing advanced, large-diameter stainless steel manifolds and optimized hydraulic water loops, the system maintains steady, high-velocity coolant circulation. This highly balanced design ensures consistent, uniform thermal dissipation, keeping the internal temperature difference between the first and last rows strictly below 2°C.

How does the container's 1-to-1 power switch design safeguard operators against high-voltage safety hazards?

To prevent dangerous electrical arcing under standard 380V operating voltages, our independent rack power cabinets utilize auto reclosing circuit breakers. This crucial design configuration ensures that operators always disconnect the breaker power before safely unplugging any active water cooled ASIC miner power cables.

How is the water pipeline system engineered to ensure reliable leak prevention during routine maintenance?

Featuring seamless stainless steel manifolds and double sealed quick connectors, this system is engineered to completely prevent any coolant leaks. The dedicated isolation valves allow operators to safely close specific racks for planned maintenance, entirely avoiding container downtime or fluid loss during operations.

2.4MW 420-Slot Enterprise Hydro Cooling Container for Large-Scale Mining

CONTAINER CAPACITY

Housed at full load
420 UNITS
Continuous electrical load
2,400 KW

Custom

Standard

Hydro

Thermal management

POWER INPUT

380V–415V AC 50/60Hz

AVAILABILITY

Typical lead time 45 days • DDP Sea Shipping Available

⚙ Compatible Models View More ›

Show 1 more models

Product Description

Custom-designed for large-scale enterprise deployments, the 2.4MW 420-Slot Antminer Hydro Cooling Container 40FT HQ represents a highly secure, heavy-duty mining infrastructure.

Built with a reinforced steel frame and fireproof insulation, this robust 40-foot container is engineered to handle up to 420 Antminer hydro series units under continuous 2400kW thermal load. It integrates pre-wired Bitmain original cabling, a dedicated Gigabit fiber switch, and auto-reclosing breakers to safeguard ASIC hardware from any electrical anomalies.

Featuring seamless stainless manifolds and redundant water loops, this fully integrated, CE-compliant solution maximizes hashing uptime, simplifies maintenance, and secures operational security for high-density, megawatt-scale BTC mining.

Core Advantages

Internal Structure of the 2.4MW Slot Antminer Hydro Container

01. re-Wired Cabling & Signals

Equips every slot with genuine Bitmain power and network cables utilizing aviation plugs, paired with a dedicated Gigabit fiber switch to ensure stable, highly organized connectivity.

2.4 MW Antminer Hydro Container CDU Circulation System

02. Redundant Dual-Loop Cooling

Built with seamless, one-piece pipes to prevent welding leaks, this dual-loop system uses red markers for hot water inlets and blue for cold outlets, running reliably if one side loses power.

Internal Racks for 2.4MW Antminer Hydro Container

03. Leak-Free Stainless Manifolds

Features space saving built-in seamless stainless steel manifolds and mini ball valves with double sealed quick connectors, ensuring zero coolant leakage during any connection and disconnection.

2.4MW Slot Antminer Hydro Container Fan

04. Reinforced & Fireproof Structure

Features motorized louvers with dust filters, a fireproof insulation lining, internal-locking fasteners, and a reinforced cross-beam base to ensure robust, secure, and stable container operations.

2.4 MW Slot Antminer Hydro Container Centralized Power Distribution Cabinet

05. Automated Reclosing Breakers

Integrates auto-reclosing circuit breakers, independent rack power controls with 1-to-1 labels, and lightning protection, enabling safe electrical operations and instant automatic shutdowns during any anomalies.

2.4MW Slot Antminer Hydro Container Leak Detection Strip

06. Leak Detection System

Equipped with a moisture-sensing immersion rope, this system detects coolant leaks and triggers instant alarms, enhancing safety and preventing potential damage in liquid-cooled mining setups.

Full Specifications

External dimensions

L:12192mm、W:2438mm、H:2896mm

Internal dimensions

L:12000mm、W:2230mm、H:2660mm

Weight

9200KG

ModelAP-HC40-A420Installed capacity420 seat
Installed powerload2310 KWPower of the light-duty vertical multistage pump30 kW
Power of the fluid replenishing pump0.2 KWTotal power of the dry cooling tower fan99.6 KW
Total power of the closed cooling tower fan33 KWTotal power of the closed cooling tower spray pump8 KW
System pipeline pressure0.2-0.4 MPAOperating temperature range of the system22-42 ℃
Coolant circulation demand of a single machine≥0.5 m³/hTotal demand for circulating coolant within the system≥2.2 m³
Molded Case Circuit Breaker250 AResidual Current Circuit Breaker630 A
Contactor9 AIntermediate relay24 V
CUL certified frequency converter380 V

Antminer 420-Slot Antminer Hydro Cooling Container Product Brochure

Complete product specifications, installation guide, and operational instructions.

Certification Standards

Our products meet leading international standards for safety, reliability, and performance.

China Classification Society

Marine & offshore compliance

UL Listed

Safety tested & certified

CSA Certified

North American compliance

CE Marking

European conformity

Recommended Power Setup

Match your container deployment with the appropriate transformer capacity.

Get Transformer Recommendation →
3000 kVA Pad Mount Three-Phase Transformer

For 1 x 2.4 MW Container

3000 kVA Three-Phase Pad-Mounted Transformer

View 3000 kVA Transformer →

Complete Cooling Solutions

We design and manufacture a complete range of hydro cooling solutions for every scale, from hydro cooling cabinets and containers to CDUs and dry coolers.

❄️ Cooling Capacity
⚙️ Miner Slots
📏 Dimensions (L × W × H)
🏢 Application

308-Slot Antminer Hydro Cooling Container

1.7 MW
308 Slots
1,2192 × 2,438 × 2,896 mm
Standard Industrial Operations

364-Slot Antminer Hydro Cooling Container

2.1 MW
364 Slots
1,2192 × 2,438 × 2,896 mm
High-Density Mining Farms

Compare

420-Slot Antminer Hydro Cooling Container

2.4 MW
420 Slots
1,2192 × 2,438 × 2,896 mm
Mega-Scale Utility Projects

480-Slot Antminer Hydro Cooling Container

2.6 MW
480 Slots
1,2192 × 2,438 × 2,896 mm
Enterprise-Class Global Facilities

Real Results from Real Miners

View All >>

2.4 MW Slot Antminer Hydro Container Deployment Case Study

12 x 2.4MW Hydro Project

Sustaining stable large-scale operations under heavy thermal loads.

+32%

Cooling Efficiency

-25%

Cooling Power Draw

$1.5M$1.5M

Annual Savings

View All >>

480-Slot Antminer Hydro Cooling Container Case Study

5 x 2.4MW Hydro Project

Achieving zero-emission hydro mining with clean geothermal energy.

+100%

Operational Uptime

-30%

Setup Time

99.9%

System Reliability

View All >>

“

"Operating 420 miners under heavy industrial voltage requires uncompromising safety. These fully UL-certified containers with automatic reclosing breakers gave our Canadian site reliable power delivery and complete operational peace of mind."

— VP of Operations, Edmonton Mining Site, Canada

"Deploying five 2.4MW containers in Iceland's rugged environment was incredibly smooth. The reinforced, fireproof structure and pre-wired cabling made on-site installation effortless, delivering immediate eco-friendly hashing."

— O&M Director, Reykjavik Mining Site, Iceland

1.2+ GW

Cumulative delivered cooling capacity

50+

Countries and regions covered

420-Slot Antminer Hydro Cooling Container FAQs

Engineered for standard 380V three phase input, the integrated PDU cabinet delivers a stable, reliable power supply. This heavy-duty system is custom configured to fully accommodate the massive 2310kW total installed load of all 420 hydro miners under continuous full-load operations safely.

Yes. For extreme climates exceeding 40°C, we recommend upgrading the integrated dry cooler with an optional wet curtain system. This restricts chip inlet water temperatures strictly below 35°C, ensuring consistent, stable full load hashrates without any thermal downclocking on extremely hot summer days.

By utilizing advanced, large-diameter stainless steel manifolds and optimized hydraulic water loops, the system maintains steady, high-velocity coolant circulation. This highly balanced design ensures consistent, uniform thermal dissipation, keeping the internal temperature difference between the first and last rows strictly below 2°C.

To prevent dangerous electrical arcing under standard 380V operating voltages, our independent rack power cabinets utilize auto reclosing circuit breakers. This crucial design configuration ensures that operators always disconnect the breaker power before safely unplugging any active water cooled ASIC miner power cables.

Featuring seamless stainless steel manifolds and double sealed quick connectors, this system is engineered to completely prevent any coolant leaks. The dedicated isolation valves allow operators to safely close specific racks for planned maintenance, entirely avoiding container downtime or fluid loss during operations.

Customize Your Hydro Cooling Solution

Share your requirements below. Our consultants will contact you via WhatsApp or email within 24 hours with a custom-matched proposal.

Project Timeline

In-stock miners will ship within 3 business days. For bulk orders, please allow an additional 1-2 days via DHL Express, UPS, FedEx, or TNT.

Pre-order miner delivery times depend on the factory schedule. Estimated delivery dates are provided on the order page, but delays may occur due to production issues.

Shipments are processed on a first-paid, first-shipped basis. Once full payment is received, we aim to ship as quickly as possible. Payments via wire transfer (T/T) may take 3-7 business days to verify, while cryptocurrency payments typically take a few hours to 1 business day.

International shipping usually takes 5-8 business days, with remote locations potentially requiring 8-10 days.

*All sales are final and non-refundable. Please understand, this is an industry standard.

Recommended Devices