15-Slot 200kW Antminer 3U Hydro Cooling Rack

Flexible 15-slot 200kW hydro cooling rack for Antminer 3U units. Expandable system designed to scale with your infrastructure while maintaining peak efficiency.

Contact us for price

In stock

Apexto is now offering U.S.-based inventory and DDP (Delivered Duty Paid) shipping for customers in the U.S. For more details, pls. contact our sales team.

Order 2 or more machines to save on shipping costs! Contact our sales team now to secure the best rates.

Trusted by

  • Apexto Mining reviews on Trustpilot
  • WhatToMine
  • Kryptex
  • NiceHash

Payment Method

  • USD
  • USDT(TRC 20)
  • KAS
  • BTC
  • ETH
  • LTC
  • DOGE
  • USDC(ERC20)

Scalable modular deployments for up to 15 Antminer 3U hydro units

CONTAINER CAPACITY

ASIC MINERS

15 UNITS

Housed at full load

TOTAL POWER

200 KW

Continuous electrical load

FORM FACTOR

Custom

Standard

COOLING

Hydro

Thermal management

POWER INPUT

380V–415V AC 50/60Hz

AVAILABILITY

In stock, ready to ship • DDP Sea Shipping Available

⚙ Compatible Models View More ›

Product Description

Designed for high-density Antminer 3U hydro mining deployments, this 15-slot rack delivers up to 200kW of cooling capacity in a compact and scalable configuration.

Its modular architecture allows the rack to be integrated with a customized CDU and heat dissipation system based on the actual miner load, site conditions, and cooling requirements. The separated cooling configuration also provides greater flexibility when planning equipment placement and future capacity expansion.

Built for professional Bitcoin mining operations, this hydro cooling rack combines efficient heat management with a practical deployment structure, making it suitable for new mining sites, facility upgrades, and phased expansion projects.

Core Advantages

Space-Efficient 15-Slot Layout

The 15-slot structure makes better use of available floor space while keeping miners neatly arranged inside the cabinet, creating a practical solution for compact warehouses and mining facilities.

Customized CDU Integration

e CDU can be customized according to miner quantity, cooling load, flow requirements, and site conditions, providing a tailored liquid circulation solution for different Antminer 3U deployment scenarios.

High-Capacity 200kW Cooling

Supporting up to 200kW of cooling capacity, the system efficiently handles the heat generated by high-performance ASIC miners, helping maintain stable operating temperatures under continuous mining workloads.

Reliable Pump Circulation System

The integrated pump system maintains consistent coolant circulation and flow throughout the cooling loop, supporting efficient heat transfer and reliable operation during continuous, high-load mining.

Dedicated 3U Miner Mounting

Engineered around Antminer 3U dimensions, the rack provides precise mounting positions and an organized internal layout, helping simplify miner installation, connection, and routine maintenance.

Modular & Scalable Architecture

The cooling architecture is designed for phased deployment, allowing additional racks, CDU capacity, or heat dissipation equipment to be incorporated as mining capacity increases and site requirements evolve.

Space-Efficient 15-Slot Layout

The 15-slot structure makes better use of available floor space while keeping miners neatly arranged inside the cabinet, creating a practical solution for compact warehouses and mining facilities.

Customized CDU Integration

e CDU can be customized according to miner quantity, cooling load, flow requirements, and site conditions, providing a tailored liquid circulation solution for different Antminer 3U deployment scenarios.

High-Capacity 200kW Cooling

Supporting up to 200kW of cooling capacity, the system efficiently handles the heat generated by high-performance ASIC miners, helping maintain stable operating temperatures under continuous mining workloads.

Reliable Pump Circulation System

The integrated pump system maintains consistent coolant circulation and flow throughout the cooling loop, supporting efficient heat transfer and reliable operation during continuous, high-load mining.

Dedicated 3U Miner Mounting

Engineered around Antminer 3U dimensions, the rack provides precise mounting positions and an organized internal layout, helping simplify miner installation, connection, and routine maintenance.

Modular & Scalable Architecture

The cooling architecture is designed for phased deployment, allowing additional racks, CDU capacity, or heat dissipation equipment to be incorporated as mining capacity increases and site requirements evolve.

Space-Efficient 15-Slot Layout

The 15-slot structure makes better use of available floor space while keeping miners neatly arranged inside the cabinet, creating a practical solution for compact warehouses and mining facilities.

Customized CDU Integration

e CDU can be customized according to miner quantity, cooling load, flow requirements, and site conditions, providing a tailored liquid circulation solution for different Antminer 3U deployment scenarios.

Modular 1-to-N Infrastructure Scalability

The 1-to-N modular design enables flexible power expansion from 200kW up to 1,000kW, allowing mining sites to scale based on evolving demand. Featuring a customized high-flow pump system and a dedicated power control cabinet, this solution ensures reliable management across multiple racks—eliminating the need for major infrastructure overhauls as your hashrate grows.

Centers Modular liquid cooling solutions
Full Specifications

External dimensions

L:800mm、W:1050mm、H:2100mm

Internal dimensions

L:750mm、W:1000mm、H:2050mm

Weight

250KG

ModelAP-A3U15Installed capacity15 Seat
Installed powerload200 kWPower of the light-duty vertical multistage pump3.5 kW
Power of the fluid replenishing pump0.2 kWTotal power of the dry cooling tower fan12.45 kW
Total power of the closed cooling tower fan2.2 kWTotal power of the closed cooling tower spray pump0.75 kW
System pipeline pressure0.2-0.4 MPAOperating temperature range of the system22-42 ℃
Coolant circulation demand of a single machine≥0.5 m³/hTotal demand for circulating coolant within the system≥0.28 m³
Residual Current Circuit Breaker400 AContactor9 A
Intermediate relay24 VCUL certified frequency converter380 V
Plug & Play with cooling system

15-Slot Antminer 3U Hydro Cooling Rack Product Brochure

Complete product specifications, installation guide, and operational instructions.

Certification Standards

Our products meet leading international standards for safety, reliability, and performance.

China Classification Society

Marine & offshore compliance

UL Listed

Safety tested & certified

CSA Certified

North American compliance

CE Marking

European conformity

Complete Cooling Solutions

We design and manufacture a complete range of hydro cooling solutions for every scale, from hydro cooling cabinets and containers to CDUs and dry coolers.

❄️ Cooling Capacity
⚙️ Miner Slots
📏 Dimensions (L × W × H)
🏢 Application

13-Slot Antminer 3U Hydro Cooling Rack

143 kW
13 Slots
850 mm × 1000 mm × 2130 mm
Compact Indoor & Office Racks

Compare

15-Slot Antminer 3U Hydro Cooling Rack

200 kW
15 Slots
8,00 × 1,050 × 2,100 mm
Modular Facility Expansion

104-Slot Antminer 3U Hydro Cooling Container

1.25 MW
104 Slots
12192 × 2438 × 2896 mm
Mid-to-Large Mining Farms

180-Slot Antminer 3U Hydro Cooling Container

2.1 MW
180 Slots
12192 × 2438 × 2896 mm
Industrial-Scale Operations

Real Results from Real Miners

View All >>

WhatsMiner mining cooling system
Almaty, Kazakhstan

8 x 200kW Industrial Project

Converting a commercial warehouse into a high-density hydro site by matching 3U-specific racks to existing 1.6MW power blocks.

+30%

Space Efficiency

-25%

Installation Time

1.6MW

Total Power

View All >>

Hydro Cooling System for ASIC Bitcoin Mining
Abu Dhabi, UAE

1-to-2 Modular Scaling

Scaling a medium-sized facility by using a single high-pressure CDU hub to drive two 15-slot 3U racks simultaneously.

+28%

O&M Savings

99.9%

Thermal Uptime

400kW

Cooling Capacity

View All >>

“

"The 1-to-2 configuration was the perfect solution for our mid-stage expansion. By using one centralized CDU to manage two 15-slot racks, we reduced the complexity of our plumbing and lowered our initial hardware costs. It keeps our 30 Antminer 3U units at a steady temperature despite the high ambient heat outside."

— Operations Manager, Oman Mining Site

"The reinforced internal rails made installing the heavy 3U miners much safer and faster for our team. We organized 15 units in each rack with zero hose clutter. Even under a full 200kW thermal load, the stainless steel manifold keeps the water pressure perfectly balanced for every machine across the row."

— Site Engineer, Almaty Mining Facility

Global Deployment

1.2+ GW

Cumulative delivered cooling capacity

Serving Mining Sites

50+

Countries and regions covered

15-Slot Antminer 3U Hydro Cooling Rack FAQs

Can this system run 15 high-power Antminer 3U Hydro miners at the same time?

Yes. The rack provides 15 dedicated positions for Antminer 3U Hydro miners and supports up to 200kW of total miner load.

The system is designed for high-density, high-power deployment. When selecting miners or performance modes, the combined miner power should remain within the 200kW system capacity.

Why does the cooling system use a 20m³/h circulation rate?

The 200kW CDU is designed with a rated circulation flow of 20m³/h to provide stable coolant delivery across a fully populated 15-miner rack.

The PLC maintains constant-flow operation with automatic pressure regulation, helping keep coolant distribution stable as operating conditions change.

Can the system start and operate in very cold climates?

Yes. The system is designed for operation from -25°C to 45°C and includes automatic heating, water refilling, and pressure-relief functions.

The integrated 4-in-1 water tank also provides constant pressure, defoaming, refilling, and heating, helping prepare the cooling loop for reliable miner startup in low-temperature environments.

What happens if there is a coolant leak, abnormal flow, pressure, or temperature?

The system continuously monitors temperature, coolant flow, pressure, and leakage through multiple sensors.

The PLC automatically manages pump and fan operation according to the target temperature, giving operators centralized visibility into cooling conditions and allowing abnormal operating conditions to be identified quickly.

Can the system maintain 200kW cooling capacity in hot climates?

Yes, the cooling configuration can be matched to the local climate.

The standard 200kW dry cooler is rated at a 35°C ambient design condition with 55°C/40°C fluid inlet and outlet temperatures. For sites with higher summer temperatures, the heat-rejection configuration can be sized according to the actual maximum ambient temperature to maintain reliable cooling performance.

Can the heat from a 200kW mining system be reused instead of discharged outdoors?

Yes. An optional stainless-steel heat exchanger can be added for heat recovery, with outlet water temperatures of up to 80°C.

Recovered mining heat can be used for applications such as building heating, swimming pools, greenhouses, aquaculture, or other processes that require hot water, turning waste heat into a usable energy source.

What electrical infrastructure should be prepared for installation?

The mining rack requires 3-phase 380–415V, 50/60Hz power, while the 200kW CDU supports 3-phase 380–480V, 50/60Hz.

Site electrical capacity should be planned for the miners together with the CDU, dry cooler, pumps, PDU, protection equipment, and suitable operating margin rather than sizing the power system only around the miners.

Can I expand from one 200kW system to a larger mining operation later?

Yes. The cooling architecture is designed for modular capacity expansion from 200kW up to 1000kW.

200kW, 600kW, 800kW, and 1000kW CDU configurations are available, allowing larger mining projects to plan cooling infrastructure around future capacity instead of rebuilding the entire system whenever additional mining power is added.

Scalable modular deployments for up to 15 Antminer 3U hydro units

CONTAINER CAPACITY

Housed at full load
15 UNITS
Continuous electrical load
200 KW

Custom

Standard

Hydro

Thermal management

POWER INPUT

380V–415V AC 50/60Hz

AVAILABILITY

In stock, ready to ship • DDP Sea Shipping Available

⚙ Compatible Models View More ›

Product Description

Designed for high-density Antminer 3U hydro mining deployments, this 15-slot rack delivers up to 200kW of cooling capacity in a compact and scalable configuration.

Its modular architecture allows the rack to be integrated with a customized CDU and heat dissipation system based on the actual miner load, site conditions, and cooling requirements. The separated cooling configuration also provides greater flexibility when planning equipment placement and future capacity expansion.

Built for professional Bitcoin mining operations, this hydro cooling rack combines efficient heat management with a practical deployment structure, making it suitable for new mining sites, facility upgrades, and phased expansion projects.

Core Advantages

Space-Efficient 15-Slot Layout

The 15-slot structure makes better use of available floor space while keeping miners neatly arranged inside the cabinet, creating a practical solution for compact warehouses and mining facilities.

Customized CDU Integration

e CDU can be customized according to miner quantity, cooling load, flow requirements, and site conditions, providing a tailored liquid circulation solution for different Antminer 3U deployment scenarios.

High-Capacity 200kW Cooling

Supporting up to 200kW of cooling capacity, the system efficiently handles the heat generated by high-performance ASIC miners, helping maintain stable operating temperatures under continuous mining workloads.

Reliable Pump Circulation System

The integrated pump system maintains consistent coolant circulation and flow throughout the cooling loop, supporting efficient heat transfer and reliable operation during continuous, high-load mining.

Dedicated 3U Miner Mounting

Engineered around Antminer 3U dimensions, the rack provides precise mounting positions and an organized internal layout, helping simplify miner installation, connection, and routine maintenance.

Modular & Scalable Architecture

The cooling architecture is designed for phased deployment, allowing additional racks, CDU capacity, or heat dissipation equipment to be incorporated as mining capacity increases and site requirements evolve.

Space-Efficient 15-Slot Layout

The 15-slot structure makes better use of available floor space while keeping miners neatly arranged inside the cabinet, creating a practical solution for compact warehouses and mining facilities.

Customized CDU Integration

e CDU can be customized according to miner quantity, cooling load, flow requirements, and site conditions, providing a tailored liquid circulation solution for different Antminer 3U deployment scenarios.

High-Capacity 200kW Cooling

Supporting up to 200kW of cooling capacity, the system efficiently handles the heat generated by high-performance ASIC miners, helping maintain stable operating temperatures under continuous mining workloads.

Reliable Pump Circulation System

The integrated pump system maintains consistent coolant circulation and flow throughout the cooling loop, supporting efficient heat transfer and reliable operation during continuous, high-load mining.

Dedicated 3U Miner Mounting

Engineered around Antminer 3U dimensions, the rack provides precise mounting positions and an organized internal layout, helping simplify miner installation, connection, and routine maintenance.

Modular & Scalable Architecture

The cooling architecture is designed for phased deployment, allowing additional racks, CDU capacity, or heat dissipation equipment to be incorporated as mining capacity increases and site requirements evolve.

Space-Efficient 15-Slot Layout

The 15-slot structure makes better use of available floor space while keeping miners neatly arranged inside the cabinet, creating a practical solution for compact warehouses and mining facilities.

Customized CDU Integration

e CDU can be customized according to miner quantity, cooling load, flow requirements, and site conditions, providing a tailored liquid circulation solution for different Antminer 3U deployment scenarios.

Modular 1-to-N Infrastructure Scalability

The 1-to-N modular design enables flexible power expansion from 200kW up to 1,000kW, allowing mining sites to scale based on evolving demand. Featuring a customized high-flow pump system and a dedicated power control cabinet, this solution ensures reliable management across multiple racks—eliminating the need for major infrastructure overhauls as your hashrate grows.

Full Specifications

External dimensions

L:800mm、W:1050mm、H:2100mm

Internal dimensions

L:750mm、W:1000mm、H:2050mm

Weight

250KG

ModelAP-A3U15Installed capacity15 Seat
Installed powerload200 kWPower of the light-duty vertical multistage pump3.5 kW
Power of the fluid replenishing pump0.2 kWTotal power of the dry cooling tower fan12.45 kW
Total power of the closed cooling tower fan2.2 kWTotal power of the closed cooling tower spray pump0.75 kW
System pipeline pressure0.2-0.4 MPAOperating temperature range of the system22-42 ℃
Coolant circulation demand of a single machine≥0.5 m³/hTotal demand for circulating coolant within the system≥0.28 m³
Residual Current Circuit Breaker400 AContactor9 A
Intermediate relay24 VCUL certified frequency converter380 V

15-Slot Antminer 3U Hydro Cooling Rack Product Brochure

Complete product specifications, installation guide, and operational instructions.

Certification Standards

Our products meet leading international standards for safety, reliability, and performance.

China Classification Society

Marine & offshore compliance

UL Listed

Safety tested & certified

CSA Certified

North American compliance

CE Marking

European conformity

Complete Cooling Solutions

We design and manufacture a complete range of hydro cooling solutions for every scale, from hydro cooling cabinets and containers to CDUs and dry coolers.

❄️ Cooling Capacity
⚙️ Miner Slots
📏 Dimensions (L × W × H)
🏢 Application

13-Slot Antminer 3U Hydro Cooling Rack

143 kW
13 Slots
850 mm × 1000 mm × 2130 mm
Compact Indoor & Office Racks

Compare

15-Slot Antminer 3U Hydro Cooling Rack

200 kW
15 Slots
8,00 × 1,050 × 2,100 mm
Modular Facility Expansion

104-Slot Antminer 3U Hydro Cooling Container

1.25 MW
104 Slots
12192 × 2438 × 2896 mm
Mid-to-Large Mining Farms

180-Slot Antminer 3U Hydro Cooling Container

2.1 MW
180 Slots
12192 × 2438 × 2896 mm
Industrial-Scale Operations

Real Results from Real Miners

View All >>

WhatsMiner mining cooling system

8 x 200kW Industrial Project

Converting a commercial warehouse into a high-density hydro site by matching 3U-specific racks to existing 1.6MW power blocks.

+30%

Space Efficiency

-25%

Installation Time

1.6MW

Total Power

View All >>

Hydro Cooling System for ASIC Bitcoin Mining

1-to-2 Modular Scaling

Scaling a medium-sized facility by using a single high-pressure CDU hub to drive two 15-slot 3U racks simultaneously.

+28%

O&M Savings

99.9%

Thermal Uptime

400kW

Cooling Capacity

View All >>

“

"The 1-to-2 configuration was the perfect solution for our mid-stage expansion. By using one centralized CDU to manage two 15-slot racks, we reduced the complexity of our plumbing and lowered our initial hardware costs. It keeps our 30 Antminer 3U units at a steady temperature despite the high ambient heat outside."

— Operations Manager, Oman Mining Site

"The reinforced internal rails made installing the heavy 3U miners much safer and faster for our team. We organized 15 units in each rack with zero hose clutter. Even under a full 200kW thermal load, the stainless steel manifold keeps the water pressure perfectly balanced for every machine across the row."

— Site Engineer, Almaty Mining Facility

1.2+ GW

Cumulative delivered cooling capacity

50+

Countries and regions covered

15-Slot Antminer 3U Hydro Cooling Rack FAQs

Yes. The rack provides 15 dedicated positions for Antminer 3U Hydro miners and supports up to 200kW of total miner load.

The system is designed for high-density, high-power deployment. When selecting miners or performance modes, the combined miner power should remain within the 200kW system capacity.

The 200kW CDU is designed with a rated circulation flow of 20m³/h to provide stable coolant delivery across a fully populated 15-miner rack.

The PLC maintains constant-flow operation with automatic pressure regulation, helping keep coolant distribution stable as operating conditions change.

Yes. The system is designed for operation from -25°C to 45°C and includes automatic heating, water refilling, and pressure-relief functions.

The integrated 4-in-1 water tank also provides constant pressure, defoaming, refilling, and heating, helping prepare the cooling loop for reliable miner startup in low-temperature environments.

The system continuously monitors temperature, coolant flow, pressure, and leakage through multiple sensors.

The PLC automatically manages pump and fan operation according to the target temperature, giving operators centralized visibility into cooling conditions and allowing abnormal operating conditions to be identified quickly.

Yes, the cooling configuration can be matched to the local climate.

The standard 200kW dry cooler is rated at a 35°C ambient design condition with 55°C/40°C fluid inlet and outlet temperatures. For sites with higher summer temperatures, the heat-rejection configuration can be sized according to the actual maximum ambient temperature to maintain reliable cooling performance.

Yes. An optional stainless-steel heat exchanger can be added for heat recovery, with outlet water temperatures of up to 80°C.

Recovered mining heat can be used for applications such as building heating, swimming pools, greenhouses, aquaculture, or other processes that require hot water, turning waste heat into a usable energy source.

The mining rack requires 3-phase 380–415V, 50/60Hz power, while the 200kW CDU supports 3-phase 380–480V, 50/60Hz.

Site electrical capacity should be planned for the miners together with the CDU, dry cooler, pumps, PDU, protection equipment, and suitable operating margin rather than sizing the power system only around the miners.

Yes. The cooling architecture is designed for modular capacity expansion from 200kW up to 1000kW.

200kW, 600kW, 800kW, and 1000kW CDU configurations are available, allowing larger mining projects to plan cooling infrastructure around future capacity instead of rebuilding the entire system whenever additional mining power is added.

Customize Your Hydro Cooling Solution

Share your requirements below. Our consultants will contact you via WhatsApp or email within 24 hours with a custom-matched proposal.

Project Timeline

In-stock miners will ship within 3 business days. For bulk orders, please allow an additional 1-2 days via DHL Express, UPS, FedEx, or TNT.

Pre-order miner delivery times depend on the factory schedule. Estimated delivery dates are provided on the order page, but delays may occur due to production issues.

Shipments are processed on a first-paid, first-shipped basis. Once full payment is received, we aim to ship as quickly as possible. Payments via wire transfer (T/T) may take 3-7 business days to verify, while cryptocurrency payments typically take a few hours to 1 business day.

International shipping usually takes 5-8 business days, with remote locations potentially requiring 8-10 days.

*All sales are final and non-refundable. Please understand, this is an industry standard.

Recommended Devices