12-Slot 66kW Antminer Hydro Cooling Rack

SKU: AP-H12 Plus

The Antminer hydro cooling system is designed to support up to 12 units of Antminer S19, S21, and S23 Hydro miners with a 66kW cooling capacity.

$6,730.00 – $8,540.00

In stock

Specification:

Apexto is now offering U.S.-based inventory and DDP (Delivered Duty Paid) shipping for customers in the U.S. For more details, pls. contact our sales team.

Order 2 or more machines to save on shipping costs! Contact our sales team now to secure the best rates.

Trusted by

  • Apexto Mining reviews on Trustpilot
  • WhatToMine
  • Kryptex
  • NiceHash

Payment Method

  • USD
  • USDT(TRC 20)
  • KAS
  • BTC
  • ETH
  • LTC
  • DOGE
  • USDC(ERC20)

Optimized residential cooling for up to 12 hydro-cooled Antminers

CONTAINER CAPACITY

ASIC MINERS

12 UNITS

Housed at full load

TOTAL POWER

66 KW

Continuous electrical load

FORM FACTOR

Custom

Standard

COOLING

Hydro

Thermal management

POWER INPUT

380V–415V AC 50/60Hz

AVAILABILITY

In stock, ready to ship • DDP Sea Shipping Available

⚙ Compatible Models View More ›

Show 8 more models

Product Description

The 12-Slot 66kW Antminer Hydro Cooling Rack PLUS is built for miners who want the same compact 12-slot hydro cooling setup with a higher standard of hardware quality. It supports up to 12 Antminer hydro miners and brings cooling, miner mounting, power connections, and water lines together in one dedicated rack.

The PLUS version places more emphasis on build quality and component selection, making it a better fit for users who prioritize solid construction and dependable long-term operation. The rack keeps the installation clean and accessible, with the cooling and power systems arranged around the miners for easier inspection and routine maintenance.

For miners moving from a basic home setup toward a more organized operation, the PLUS provides a practical bridge between residential mining and professional rack deployment.

Core Advantages

liquid cooling for antminer mining

01. Reinforced 12-Slot Rack Frame

This 12-slot rack features a black-coated reinforced frame. It centralizes 12 Antminer hydro units in one place, providing an organized structure for cable and hose management in home or workshop environments.

Hydro miner cooling solution Crypto MINING

02. Industrial Stainless Steel Manifold

The 304 stainless steel manifold is built for long-term durability. It features precision-welded pipes and manual shut-off valves for each slot, ensuring balanced coolant flow and reliable leak-free hashing.

ANTMINER hydro cooling miners solution

03. Organized Power Distribution Hub

The power management section utilizes automatic reclosing breakers for enhanced safety. This individual switch layout provides over-current protection and allows maintenance on specific miners without total downtime.

Hydro Cooling Suite Support Antminer

04. Integrated CDU Circulation Module

The integrated CDU module houses an industrial pump and a stainless steel expansion tank. It maintains stable fluid pressure and ensures the 66kW heat load is exported efficiently through the whole cooling loop.

Hydro Cooled Rack For Bitcoin Mining

05. Automated PLC Management System

The intelligent PLC system monitors real-time fluid pressure, temperature, and flow rates. It features automated speed regulation for fans and pumps, ensuring the whole rack maintains a constant thermal balance safely.

Hydro Cooling Solution dry cooler

06. V-Type Corrosion-Resistant Cooler

This V-type cooler uses a corrosion-resistant aluminum tube-fin structure. Its anti-clogging design ensures stable heat exchange in environments with impurities or corrosive media reliably for long-term mining operations.

Full Specifications

External dimensions

L:900mm、W:1000mm、H:2000mm

Internal dimensions

L:850mm、W:950mm、H:1950mm

Weight

350KG

ModelAP-H12 PlusInstalled capacity12 Seat
Heat Dissipation Capacity66 kWPower of the light-duty vertical multistage pump2.2 kW
Power of the fluid replenishing pump0.2 kWTotal power of the dry cooling tower fan4.15 kW
Total power of the closed cooling tower fan0.55 kWTotal power of the closed cooling tower spray pump0.75 kW
System pipeline pressure0.2-0.4 MapOperating temperature range of the system22-42 ℃
Coolant circulation demand of a single machine≥0.5 m³/hTotal demand for circulating coolant within the system≥0.12 m³
Molded Case Circuit Breaker160 AContactor9 A
Intermediate relay160 VCUL certified frequency converter380 V
Dry Cooler
Cooling Capacity66 kWFan Quantity1 Pcs
Working FluidEthylene GlycolFluid Flow Rate8.4 m³/h
Inlet / Outlet Temperature48–40 ℃Ambient Temperature38 ℃
Operating / Max Pressure0.25 / 0.4 MPaDry Cooling Tower Fan Total Power8.3 kW
Dry Cooler Dimensions1950*1920*1710 mmDry Cooler Weight388 KG

12-Slot Antminer Hydro Cooling Rack Product Brochure

Complete product specifications, installation guide, and operational instructions.

Hydronic Heat Recovery Solution

Hydro cooling systems that double as flexible heating solutions—turning mining heat into efficient warmth anywhere it's needed.

Key Benefits & Applications:

  • Versatile Heating Integration: Seamlessly supports underfloor heating, radiators, swimming pools, and other applications—offering efficient warmth across different environments.
  • Customizable Options: Heating modules can be tailored to match your building layout, heating system, and specific usage requirements.
  • Energy Reuse: Repurpose mining-generated heat to reduce energy waste and lower overall heating costs.
Hydro Cooled Bitcoin Mining Hydronic Heating Solution

Complete Cooling Solutions

We design and manufacture a complete range of hydro cooling solutions for every scale, from hydro cooling cabinets and containers to CDUs and dry coolers.

❄️ Cooling Capacity
⚙️ Miner Slots
📏 Dimensions (L × W × H)
🏢 Application

Compare

12-Slot Antminer Hydro Cooling Rack

66 kW
12 Slots
9,00 × 10,00 × 2,000 mm
Advanced Home Infrastructure

9-Slot Antminer Hydro Cooling Rack

50 kW
9 Slots
8,00 × 8,00 × 1,600 mm
Professional Home Setups

6-Slot Antminer Hydro Cooling Rack

35 kW
6 Slots
8,00 × 8,00 × 1,450 mm
Standard Garage Operations

4-Slot Antminer Hydro Cooling Rack

26 kW
4 Slots
1,070 × 7,00 × 1,390 mm
Compact Entry-Level Mining

12-Slot Home Hydro Cooling Rack FAQs

Does 12 slots mean I can run any 12 Antminer Hydro miners?

Not necessarily. The system provides 12 physical miner slots, but the actual number of miners that can operate simultaneously depends on their combined power consumption.

The total miner load should remain within the system's 66kW capacity. For higher-power Hydro models, please confirm the total power consumption before deployment.

How is coolant flow distributed across 12 miners?

The system uses a centralized circulation loop and manifold to distribute coolant to each miner.

Proper flow balancing is important in a multi-miner setup to ensure every miner receives sufficient coolant. The system has a rated circulation flow of 6m³/h, while individual miner flow requirements depend on the specific Antminer Hydro model.

If one miner needs maintenance, do all 12 miners have to be shut down?

No. Individual miner branches can be isolated for inspection or maintenance without shutting down the entire cooling system.

This makes it easier to replace or service one miner while keeping the remaining miners in operation, reducing unnecessary downtime.

Why is a dry cooler recommended for a 12-miner system?

For a 12-miner deployment, a dry cooler offers a simpler and more cost-effective heat-rejection solution.

Compared with a closed cooling tower, it requires less supporting equipment and is easier to install and maintain. Closed cooling towers are generally more suitable for larger centralized mining deployments.

Can the system maintain cooling performance in hot weather?

Cooling performance depends on total miner load, outdoor temperature, coolant temperature, airflow, and dry cooler operating conditions.

The matched cooling system should be selected according to the site's maximum summer ambient temperature. For very hot regions, we recommend confirming the actual site conditions before finalizing the cooling configuration.

How much additional power does the cooling system consume?

The cooling system consumes additional electricity beyond the miners themselves.

Power is required for the circulation pumps, control system, and dry cooler fans. These auxiliary loads should be included when calculating the total electrical capacity required for the complete 12-miner installation.

How are all 12 miners monitored and managed?

The system uses PLC-based intelligent control and supports MODBUS-RTU communication.

Operating parameters such as system status, temperature, flow, and other cooling conditions can be monitored centrally, making it easier to manage a multi-miner Hydro installation and identify abnormal operating conditions.

What coolant and routine maintenance are required?

The system uses an ethylene-glycol-based cooling solution suitable for the installation environment.

Routine maintenance includes checking coolant quality and level, system pressure, flow distribution, pumps, valves, hoses, pipe connections, leaks, and keeping the dry cooler clean with unobstructed airflow.

Optimized residential cooling for up to 12 hydro-cooled Antminers

CONTAINER CAPACITY

Housed at full load
12 UNITS
Continuous electrical load
66 KW

Custom

Standard

Hydro

Thermal management

POWER INPUT

380V–415V AC 50/60Hz

AVAILABILITY

In stock, ready to ship • DDP Sea Shipping Available

⚙ Compatible Models View More ›

Show 8 more models

Product Description

The 12-Slot 66kW Antminer Hydro Cooling Rack PLUS is built for miners who want the same compact 12-slot hydro cooling setup with a higher standard of hardware quality. It supports up to 12 Antminer hydro miners and brings cooling, miner mounting, power connections, and water lines together in one dedicated rack.

The PLUS version places more emphasis on build quality and component selection, making it a better fit for users who prioritize solid construction and dependable long-term operation. The rack keeps the installation clean and accessible, with the cooling and power systems arranged around the miners for easier inspection and routine maintenance.

For miners moving from a basic home setup toward a more organized operation, the PLUS provides a practical bridge between residential mining and professional rack deployment.

Core Advantages

liquid cooling for antminer mining

01. Reinforced 12-Slot Rack Frame

This 12-slot rack features a black-coated reinforced frame. It centralizes 12 Antminer hydro units in one place, providing an organized structure for cable and hose management in home or workshop environments.

Hydro miner cooling solution Crypto MINING

02. Industrial Stainless Steel Manifold

The 304 stainless steel manifold is built for long-term durability. It features precision-welded pipes and manual shut-off valves for each slot, ensuring balanced coolant flow and reliable leak-free hashing.

ANTMINER hydro cooling miners solution

03. Organized Power Distribution Hub

The power management section utilizes automatic reclosing breakers for enhanced safety. This individual switch layout provides over-current protection and allows maintenance on specific miners without total downtime.

Hydro Cooling Suite Support Antminer

04. Integrated CDU Circulation Module

The integrated CDU module houses an industrial pump and a stainless steel expansion tank. It maintains stable fluid pressure and ensures the 66kW heat load is exported efficiently through the whole cooling loop.

Hydro Cooled Rack For Bitcoin Mining

05. Automated PLC Management System

The intelligent PLC system monitors real-time fluid pressure, temperature, and flow rates. It features automated speed regulation for fans and pumps, ensuring the whole rack maintains a constant thermal balance safely.

Hydro Cooling Solution dry cooler

06. V-Type Corrosion-Resistant Cooler

This V-type cooler uses a corrosion-resistant aluminum tube-fin structure. Its anti-clogging design ensures stable heat exchange in environments with impurities or corrosive media reliably for long-term mining operations.

Full Specifications

External dimensions

L:900mm、W:1000mm、H:2000mm

Internal dimensions

L:850mm、W:950mm、H:1950mm

Weight

350KG

ModelAP-H12 PlusInstalled capacity12 Seat
Heat Dissipation Capacity66 kWPower of the light-duty vertical multistage pump2.2 kW
Power of the fluid replenishing pump0.2 kWTotal power of the dry cooling tower fan4.15 kW
Total power of the closed cooling tower fan0.55 kWTotal power of the closed cooling tower spray pump0.75 kW
System pipeline pressure0.2-0.4 MapOperating temperature range of the system22-42 ℃
Coolant circulation demand of a single machine≥0.5 m³/hTotal demand for circulating coolant within the system≥0.12 m³
Molded Case Circuit Breaker160 AContactor9 A
Intermediate relay160 VCUL certified frequency converter380 V
Dry Cooler
Cooling Capacity66 kWFan Quantity1 Pcs
Working FluidEthylene GlycolFluid Flow Rate8.4 m³/h
Inlet / Outlet Temperature48–40 ℃Ambient Temperature38 ℃
Operating / Max Pressure0.25 / 0.4 MPaDry Cooling Tower Fan Total Power8.3 kW
Dry Cooler Dimensions1950*1920*1710 mmDry Cooler Weight388 KG

12-Slot Antminer Hydro Cooling Rack Product Brochure

Complete product specifications, installation guide, and operational instructions.

Hydronic Heat Recovery Solution

Hydro cooling systems that double as flexible heating solutions—turning mining heat into efficient warmth anywhere it's needed.

Key Benefits & Applications:

  • Versatile Heating Integration: Seamlessly supports underfloor heating, radiators, swimming pools, and other applications—offering efficient warmth across different environments.
  • Customizable Options: Heating modules can be tailored to match your building layout, heating system, and specific usage requirements.
  • Energy Reuse: Repurpose mining-generated heat to reduce energy waste and lower overall heating costs.

Complete Cooling Solutions

We design and manufacture a complete range of hydro cooling solutions for every scale, from hydro cooling cabinets and containers to CDUs and dry coolers.

❄️ Cooling Capacity
⚙️ Miner Slots
📏 Dimensions (L × W × H)
🏢 Application

Compare

12-Slot Antminer Hydro Cooling Rack

66 kW
12 Slots
9,00 × 10,00 × 2,000 mm
Advanced Home Infrastructure

9-Slot Antminer Hydro Cooling Rack

50 kW
9 Slots
8,00 × 8,00 × 1,600 mm
Professional Home Setups

6-Slot Antminer Hydro Cooling Rack

35 kW
6 Slots
8,00 × 8,00 × 1,450 mm
Standard Garage Operations

4-Slot Antminer Hydro Cooling Rack

26 kW
4 Slots
1,070 × 7,00 × 1,390 mm
Compact Entry-Level Mining

12-Slot Home Hydro Cooling Rack FAQs

Not necessarily. The system provides 12 physical miner slots, but the actual number of miners that can operate simultaneously depends on their combined power consumption.

The total miner load should remain within the system's 66kW capacity. For higher-power Hydro models, please confirm the total power consumption before deployment.

The system uses a centralized circulation loop and manifold to distribute coolant to each miner.

Proper flow balancing is important in a multi-miner setup to ensure every miner receives sufficient coolant. The system has a rated circulation flow of 6m³/h, while individual miner flow requirements depend on the specific Antminer Hydro model.

No. Individual miner branches can be isolated for inspection or maintenance without shutting down the entire cooling system.

This makes it easier to replace or service one miner while keeping the remaining miners in operation, reducing unnecessary downtime.

For a 12-miner deployment, a dry cooler offers a simpler and more cost-effective heat-rejection solution.

Compared with a closed cooling tower, it requires less supporting equipment and is easier to install and maintain. Closed cooling towers are generally more suitable for larger centralized mining deployments.

Cooling performance depends on total miner load, outdoor temperature, coolant temperature, airflow, and dry cooler operating conditions.

The matched cooling system should be selected according to the site's maximum summer ambient temperature. For very hot regions, we recommend confirming the actual site conditions before finalizing the cooling configuration.

The cooling system consumes additional electricity beyond the miners themselves.

Power is required for the circulation pumps, control system, and dry cooler fans. These auxiliary loads should be included when calculating the total electrical capacity required for the complete 12-miner installation.

The system uses PLC-based intelligent control and supports MODBUS-RTU communication.

Operating parameters such as system status, temperature, flow, and other cooling conditions can be monitored centrally, making it easier to manage a multi-miner Hydro installation and identify abnormal operating conditions.

The system uses an ethylene-glycol-based cooling solution suitable for the installation environment.

Routine maintenance includes checking coolant quality and level, system pressure, flow distribution, pumps, valves, hoses, pipe connections, leaks, and keeping the dry cooler clean with unobstructed airflow.

Customize Your Hydro Cooling Solution

Share your requirements below. Our consultants will contact you via WhatsApp or email within 24 hours with a custom-matched proposal.

Project Timeline

In-stock miners will ship within 3 business days. For bulk orders, please allow an additional 1-2 days via DHL Express, UPS, FedEx, or TNT.

Pre-order miner delivery times depend on the factory schedule. Estimated delivery dates are provided on the order page, but delays may occur due to production issues.

Shipments are processed on a first-paid, first-shipped basis. Once full payment is received, we aim to ship as quickly as possible. Payments via wire transfer (T/T) may take 3-7 business days to verify, while cryptocurrency payments typically take a few hours to 1 business day.

International shipping usually takes 5-8 business days, with remote locations potentially requiring 8-10 days.

*All sales are final and non-refundable. Please understand, this is an industry standard.

Recommended Devices